Figure 14. Configuration mode screen
Click Cancel to go to the Information mode screen and then continue to step 2.
Important
The ServeRAID controller should be initialized only one time, when the controller is first installed.
Initializing the controller removes all configuration information from NVRAM. This information
includes the SCSI IDs, the Controller host ID and the Cluster partner host ID, and the array
information. This point is especially important if the Windows NT system startup drive is attached
to the IBM ServeRAID controller. If the initialization occurs after the startup drive array has been
created, the array information will be removed and the system will no longer start in Windows NT.
2. Click the first ServeRAID controller that you are configuring in the Main Tree.
3. Select Restore to factory default settings from the Actions menu.
4. When the initialization is complete, a message appears at the bottom of the screen saying that the
initialization was successful.
5. Click the second ServeRAID controller that you are configuring in the Main Tree.
6. Select Restore to factory default settings from the Actions menu.
7. When complete, a message appears at the bottom of the screen saying that the initialization was
successful.