LP GAS HOOK-UP - CONT'D.
DO NOT PLACE MORE THAN ONE CYLINDER IN THE ENCLOSURE AT ANY TIME.
DO NOT STORE SPARE LP GAS CYLINDER UNDER OR NEAR THIS APPLIANCE.
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
FAILURE TO DO SO, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY OCCUR.
If LP gas is the desired gas type for your Pizza Oven, please note that Delta Heat does not
provide the LP gas cylinder. If a LP gas cylinder was to be used in this installation, we strongly recom-
mend the following guidelines:
An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor
level. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP
gas supply cylinder in place. This shall be accomplished by one of the following:
a. One side of the enclosure shall be fully open; or
b. For a cylinder enclosure having four sides, a top and a bottom, and intended for installation in
a built-in enclosure:
i. at least one ventilation opening shall be provided on the exposed exterior side of the enclo-
sure located within 5 in (127mm) of the top of the enclosure and unobstructed. The open-
ing(s) shall have a total free area of not less than 1 in²/lb (14.2 cm²/kg) of stored fuel capacity.
ii. at least one ventilation opening shall be provided on the exposed, exterior side of the en-
closure 1 in (25.4 mm) or less from the floor level and shall have a total free area of not less
than 1/2 in²/lb (7.1 cm²/kg) of stored fuel capacity. The upper edge shall be no more than 5 in
(127 mm) above the floor level.
iii. every opening shall have a minimum dimension so as to permit the entrance of a 1/8 in (3.2
mm) rod.
LP GAS CONNECTION TO BULK LP PIPED SYSTEMS:
A bulk LP piped system is typically a central LP tank detached from the home that feeds the
entire household. Those systems are normally equipped with a high pressure regulator at the tank
and low pressure regulators close to the home.
All gas line connections must comply with the Standard for Connectors for Outdoor Gas Appli-
ances and Manufactured Homes, ANSIZ21.75, CSA 6.27, and suitable for outdoor installation. The
maximum length of the connection shall be 6 ft. (1.82 m).
4 | www.deltaheat.com
DO NOT USE A DENTED OR RUSTED LP CYLINDER.