6   CONTROL PANEL
6.2

Internal control panel

1 CC/CV switch
2 Circuit breaker
3 Main fuse, 10 A
4 Power switch
6.3

Function explanation

Gas purging
Gas purging is used when measuring the gas flow or to flush any air or moisture from
the gas hoses before welding starts. Gas purging takes place for as long as the button is
held depressed and takes place without voltage or wire feed starting.
Wire inching
Wire inching is used when feeding wire without applying a welding voltage. The wire is
fed as long as the button is depressed.
2-stroke
With 2-stroke, gas pre-flow starts when the welding torch trigger switch is pressed. The
welding process then starts. Releasing the trigger switch stops welding entirely and
starts gas post-flow.
0446 680 001
5 2-stroke or 4-stroke selection switch
6 Gas purging / Wire inching switch
7 Knob for setting the gas flow rate (optional)