5   OPERATION
5.6

Changing feed rollers

When changing to a different type of wire, the feed rollers should also be changed to match the new
type of wire. For more information about correct feed rollers depending on wire diameter and type, see
the WEAR PARTS appendix. For tips about easy access to essential wear parts, see the "Wear parts
storage compartment" section in this manual.
1) Open the left door of the wire feeder.
2) Unlock the feed rollers to be exchanged, by rotating the roller quick lock (A) for each roller.
3) Relieve the pressure on the feed rollers, by folding the tensioner units (B) down and thereby
releasing the swing arms (C).
4) Remove the feed rollers and install the correct ones (according to the WEAR PARTS appendix).
5) Reapply the pressure on the feed rollers, by pushing the swing arms (C) down and secure them
using the tensioner units (B).
6) Lock the rollers by rotating the roller quick locks (A).
7) Close and lock the left door of the wire feeder.
5.7

Changing the wire guides

When changing to a different type of wire, the wire guides may need to be changed to match the new
type of wire. For information about the correct wire guides depending on wire diameter and type, see
the "WEAR PARTS" appendix. (For a tip to easy access to necessary wear parts, see the "Wear parts
storage compartment" section in this manual.)