Table of faults
Table 11- List of faults
Fault code
Fault
A01
No burner ignition
Flame present signal with
A02
burner off
F05
Fan fault
No flame after the ignition
A06
phase
Overtemperature protec-
A08
tion intervention
46
BlueHelix HiTech RRT C
Possible cause
No gas
Ignition/detection electrode
fault
Insufficient gas supply pres-
sure
Trap blocked
Air/fume ducts obstructed
Wrong calibration
Faulty gas valve
Electrode fault
Card fault
No 230V power supply
Tachometric signal interrup-
ted
Fan damaged
Ionization electrode fault
Flame unstable
air/fume ducts obstructed
Trap blocked
Wrong calibration
Insufficient gas supply pres-
sure
Flow or return sensors inco-
rrectly positioned or dama-
ged
No water circulation in the
system
Air in the system
cod. 3541V691 - Rev. 00 - 04/2022
Cure
Check the regular gas flow to the boiler
and that the air has been eliminated from
the pipes
Check the wiring of the electrode and that
it is correctly positioned and free of any
deposits; replace the electrode if neces-
sary.
Check the gas supply pressure
Check the trap and clean it if necessary
Remove the obstruction from the flue,
fume extraction ducts, air inlet and termi-
nals.
Do the Calibration procedure [AUTO
SETUP].
Check the gas valve and replace it if
necessary
Check the ionization electrode wiring
Check the condition of the electrode
Electrode to ground
Cable to ground
Check the trap and clean it if necessary
Check the card
Check the 5-pin connector wiring
Check the fan and replace it if necessary
Check the position of the ionization elec-
trode, free it from any encrustations and
do the Calibration procedure [AUTO
SETUP]. Replace the electrode if neces-
sary.
Check the burner
Remove the obstruction from the flue,
fume extraction ducts, air inlet and termi-
nals
Check the trap and clean it if necessary
Do the Calibration procedure [AUTO
SETUP].
Check the gas supply pressure
Check the correct positioning and opera-
tion of the sensors and replace them if
necessary.
Check the circulating pump
Vent the system