Ferroli BlueHelix HiTech RRT C Instructions For Use, Installation & Maintenance page 35

Table of Contents

Advertisement

BlueHelix HiTech RRT C
Index
Description
b29
Restore Factory Values
P30
Heating ramp
P31
Heating standby time
P32
Heating Post-Circulation
P33
Pump operation
P34
Pump modulation DeltaT
P35
Modulating pump min. speed
P36
Modulating pump start speed
P37
Modulating pump max. speed
Pump deactivation temperature
P38
during Post-Circulation
Pump activation hysteresis tem-
P39
perature during Post-Circulation
P40
Heating user max. setpoint
P41
Max. output in heating
P42
Burner shutdown in DHW
Comfort mode activation tempe-
P43
rature
Comfort mode deactivation hys-
P44
teresis
P45
DHW standby time
P46
DHW user max. setpoint
P47
DHW pump Post-Circulation
P48
Max. output in DHW
P49
Not implemented (b01=2)
P50
Not implemented (b01=2)
Burner shutdown in DHW
P51
(P42=2)
P52
Burner ignition in DHW (P42=2)
P53
Solar standby time
System pre-circulation time in
P54
heating
P55
System filling mode
Minimum system pressure limit
P56
value
P57
System nominal pressure value
Maximum system pressure limit
P58
value
Circulating pump deactivation
P59
with OpenTherm
P60
Frost protection power
P61
Minimum power
EN
Range
See "* Restore Factory Values" on page 37 .
10÷80
(ex. 10=20°C/min, 20=12°C/min, 40=6°C/min, 80=3°C/min)
0 ÷ 10 minutes
0 ÷ 255
(Multiply the value by 10. Example 15 x 10 = 150 seconds)
0 = Continuous pump (active only in winter mode)
1 = Modulating pump
0 ÷ 40°C
30 ÷ 100%
90 ÷ 100%
90 ÷ 100%
0 ÷ 100°C
0 ÷ 100°C
20 ÷ 90°C
0 ÷ 100%
0 = Fixed
1 = Linked to setpoint
2 = Solar
0 ÷ 80°C
0 ÷ 20°C
30 ÷ 255 seconds
40 ÷ 65°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
0 ÷ 100
OFF = DHW user setpoint + P51
0 ÷ 100
ON = DHW user setpoint - P52
0 ÷ 255 seconds
0 ÷ 60 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure sensor)
5-20 bar/10 (Only for boilers with water pressure sensor)
25-35 bar/10 (Only for boilers with water pressure sensor)
0 = Circulating pump activated in heating
1 = Circulating pump deactivated in heating with request from Open-
Therm only
0 ÷ 50% (0 = minimum)
0 ÷ 50% (0 = minimum)
cod. 3541V691 - Rev. 00 - 04/2022
Default
0
40
4
15
1
20
30
90
100
55
25
80
24 kW = 80
28 kW = 85
34 kW = 90
0
40
20
120
55
30
100
--
--
10
10
10
30
0
4
7
28
0
0
0
35