Display adjustment menu [Display]
In this menu it is possible to set some display parame-
ters.
[Contrast] - Contrast adjustment
[Brightness] - Brightness adjustment
[Backlight time] - Display lighting duration
[Lock time]* - Key lock
After keypad inactivity for a time equal to the
set value (minutes), the symbol
and the buttons are inhibited.
To reactivate the keypad, press the bu-
ttons
and
symbol
* This function is available from version DSP
FW 1.03.
[Reset] - Restore factory values
Sliding Temperature
When the external probe (optional) is installed, the boiler adjustment system works with "Sliding Temperature". In this
mode, the heating system temperature is regulated according to weather conditions, to ensure high comfort and energy
efficiency throughout the year. In particular, as the outside temperature increases the system flow temperature decrea-
ses according to a specific "compensation curve".
With "Sliding Temperature", the temperature set using the heating buttons (details 3 and 4 - fig. 1) becomes the maxi-
mum system flow temperature. It is advisable to set a maximum value to allow system adjustment throughout its useful
operating range.
The boiler must be adjusted at the time of installation by qualified personnel. However, the user can make any further
adjustments necessary to optimize comfort levels.
Compensation curve and curve offset
From the main screen, press the button
heating select the installer menu [SERVICE] and confirm with the button
menu [SERVICE]" on page 12 ) and press the button
matic curves setting [OTC] and confirm by pressing the button
Curve: select this item and use the buttons
DHW to adjust the desired curve from 1
to 10.
By adjusting the curve to 0, the sliding tem-
perature adjustment is disabled (see fig. 24).
Offset: Access this sub-menu to access parallel off-
set of the curves using the buttons
DHW. Refer to fig. 25 for the characteris-
tics.
OFF:
This item gives access to the "external tem-
perature shutdown" value. Use the buttons
and
0 to 40°C), if set to 0 the function is disabled.
Ignition occurs when the temperature of the
external probe is more than 2°C lower than
the set temperature.
14
appears
simultaneously until the
disappears (about 2 sec.).
to access the navigation menu [MENU]. Using the buttons
DHW to modify the value (from
cod. 3541V691 - Rev. 00 - 04/2022
BlueHelix HiTech RRT C
Contrast
Brightness
Backlight time
Lock time
Reset
. Using the buttons
.
and
Curve
Offset
OFF
and
DISPLAY
5
Max
10m
OFF
fig. 22
. Enter the password (see "Installer
and
heating select the menu Cli-
OTC
fig. 23
and
EN