BlueHelix HiTech RRT C
Main exchanger replacement
Before carrying out the following instructions it is advisable to protect the room and the boiler's electrical box
A
against accidental water spillage.
B
Disconnect the power supply and close the gas cock ahead of the valve
Disconnect the fume sensor connector 1.
Disconnect the fan connector
Disconnect the connector of the ignition electrode
connected to the board.
Drain the water from the boiler heating circuit.
Remove the flue connection (concentric or acces-
sory for separate ducts)
Remove the fan
Remove the clips of the two pipes on the exchan-
ger, pump and hydraulic unit
Loosen the 2 bottom screws "5" securing the ex-
changer to the frame (fig. 52)
Remove the 2 top screws "6" securing the ex-
changer to the frame (fig. 53)
Remove the exchanger
Insert the new exchanger, resting it on the bottom
screws "5"
EN
For assembly, proceed in reverse order