Refrigerant Diagram - Ferroli OMNIA S HYBRID H 3.2 Installation, Use & Maintenance Manual

Indoor wall unit for split reversible hybrid heat pumps which can be combined with an outdoor dhw heater
Table of Contents

Advertisement

OMNIA S HYBRID H 3.2

15. REFRIGERANT DIAGRAM

LEGEND
E1
Compressor
E2
4-way valve
E3
Gas-liquid separator
E4
Heat exchange air side
E5
Electronic expansion valve
E6
Single-direction electromagnetic valve
E7
Filter
E8
Drain temperature probe
Indoor unit
45
°C
25
°C
HP
LP
Cod. 3542B230 - Rev. 00 - 02/2022
Outdoor unit
fig. 65 -
E9
External temperature probe
E10
External exchanger probe
E11
Stop valve (gas)
E12
Stop valve (liquid)
E13
High pressure switch
E14
Low pressure switch
E15
Pressure sensor
E16
Capillary
E17
Extraction temperature probe