Advertisement

Thank you for purchasing this product.
The FERROLI instantaneous gas water heater you have chosen was designed and manufactured by our specialists
and controlled in every stage according to the strictest quality standards, to meet your needs.
To ensure best use of your new FERROLI instantaneous gas water heater, please read these instructions carefully.
CONTENTS
USER INSTRUCTIONS .............................................................................................................. ................5
ELECTRONIC WATER HEATER ........................................................................................................ . ............. 5
CONTROL PANEL.................................................................................................................. .................... 6
INSTALLER INSTRUCTIONS ......................................................................................................... .........6
PLACE OF INSTALLATION.......................................................................................................... . .................... 6
GAS AND WATER CONNECTIONS ................................................................................................................. 6
WALL MOUNTING.................................................................................................................. . .......................... 7
MAIN DIMENSIONS ................................................................................................................ . ......................... 7
FLUE GAS EXHAUST ............................................................................................................... . ....................... 8
EXTERNAL CASING ASSEMBLY....................................................................................................... . ............. 8
CHECK AND DELIVERY ................................................................................................................................... 8
FUME EXHAUST SAFETY DEVICE ..................................................................................................... . .......... 8
TECHNICAL DATA ................................................................................................................. . .......................... 9
SERVICE AND MAINTENANCE........................................................................................................ ....10
CONVERSION ..................................................................................................................... ...................... 10
WIRING DIAGRAM ................................................................................................................. ................11
LEVELS.................................................................................................. 3
2
ZEFIRO
EN

Advertisement

Table of Contents
loading

Summary of Contents for Ferroli Zefiro C11

  • Page 1: Table Of Contents

    The FERROLI instantaneous gas water heater you have chosen was designed and manufactured by our specialists and controlled in every stage according to the strictest quality standards, to meet your needs. To ensure best use of your new FERROLI instantaneous gas water heater, please read these instructions carefully. CONTENTS DESCRIPTION, EQUIPMENT LEVELS....................
  • Page 2: Description, Equipment Levels

    ZEFIRO '(6&5,37,21(48,30(17/(9(/6 The FERROLI water heater has been designed and built to offer the convenience (with correct use) of hot water. The unit consists of the following elements (see attached table). 1. Incorporated draught diverter: Ensures correct combustion, even when the draught changes in the flue.
  • Page 3 ZEFIRO Zefiro C11 Ψ 110 Zefiro C14 Ψ 130 1 = Hot water outlet: R 1/2". 2 = Gas inlet: R 1/2". 3 = Cold water inlet: R 1/2".
  • Page 4: User Instructions

    ZEFIRO 86(5,16758&7,216 ELECTRONIC WATER HEATER -Preliminary checks Make sure the hot water taps are closed. Open the water heater gas cock, located on the gas connection to the unit. Make sure the 1.5 V batteries are in place, with the correct polarity (+ and -), and that the safety seal has been removed.
  • Page 5: Control Panel

    ZEFIRO &21752/3$1(/ ,167$//(5,16758&7,216 Correct operation of the water heater depends largely on CORRECT installation. INSTALLATION MUST ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF THE CURRENT LAWS, THE NATIONAL AND LOCAL REGULATIONS AND THE RULES OF PROPER WORKMANSHIP.
  • Page 6: Wall Mounting

    ZEFIRO 3. WALL MOUNTING Fix the plugs and hooks on the wall, in a central position vertical to the appliance, as shown in the figure below. Mark the position of the bottom screws Hang the water heater on the plugs+hooks and tighten the screws for fixing the unit to the wall. Connect the hot and cold water flexible tubes, remembering to check their tightness.
  • Page 7: Flue Gas Exhaust

    ZEFIRO 4. FLUE GAS EXHAUST. The size of the flue gas exhaust pipe must be Ψ 110 mm (Zefiro C11), Ψ 130 mm (Zefiro C14). The mass flows for calculating the flue are given in the technical data table on page 9. Flue gas exhaust check: with the water heater operating at nominal power, using a cold mirror or any other approved measuring device, check the tightness of the entire flue gas exhaust system.
  • Page 8: Technical Data

    ZEFIRO TECHNICAL DATA Model ZEFIRO-11 ZEFIRO-14 Gas Category II2H3+ II2H3+ Type of unit B11BS B11BS Type of installation Internal Internal Max heat input 21,1 26,8 Min heat input 10,7 Max heat output 18,9 23,8 Min heat output Pmax efficiency 89,0 88,8 Burner injectors G20 n°...
  • Page 9: Service And Maintenance

    Local After-Sales Technical Service. FERROLI declines any liability for damage or injury caused by unqualified and unauthorised people tampering with the unit. NB : The water heater is arranged for a specific gas type, as indicated on the dataplate. If modification is...
  • Page 10: Wiring Diagram

    ZEFIRO WIRING DIAGRAM...
  • Page 11 FERROLI S.p.A. Via Ritonda 78/a 37047 San Bonifacio - Verona - ITALY www.ferroli.it...

This manual is also suitable for:

Zefiro c14Zefiro-11Zefiro-14

Table of Contents