OMNIA S HYBRID H 3.2
Index
Icon
Description
5
timer
6
Eco function
7
Photovoltaic FV
SG smart grid
Maximum energy consumption
8
Anti-freeze
Defrost
Silent mode
9
DHW symbol
10
Anti-legionella
11
Solar panels
DHW electric boiler heater
12
DHW temperature - DHW set
point
13
Heating symbol
Cooling symbol
14
Holiday mode
15
- Delivery set point
- Delivery set point zone 1
- Delivery set point zone 2
16
Zone 1 indicator
17-18-
Selection
19
DHW-Z1-Z2 to change set point
20
Zone 2 indicator

8.3 Switching DHW and system on and off

Switching on or off (ON / OFF) is done with the SW5 key.
When a mode is turned off, OFF appears in place of the current display.
When a mode is turned on, the current display appears.
There are two possibilities of switching on / off: for single function and general.
Single function power off / on:
- Select DHW and with 1sec pressure on OFF, only DHW switches off/on
- Select single zone and with 1sec pressure on OFF, only DHW switches off/on
- Select Z1 and with 1sec pressure on OFF, only Z1 switches off/on
- Select Z2 and with 1sec pressure on OFF, only Z2 switches off/on
General shut-down:
When OFF is pressed for > 3 sec, all DHW and zones are switched on or off.
Enabled when one of the timer functions is active
Enabled when the ECO function is active
Enabled when FV dig-in=closed
Enabled when SG dig-in=closed
Appears when EVU and SG dig-in = both open.
Enabled when the anti-freeze is in progress
Enabled when the defrost is in progress
Enabled when the silent mode is in progress
DHW mode
Anti-legionella in progress
Enabled when the thermal solar panel is operating Shared position on the display.
Enabled when the DHW electric boiler heater is
operating.
Displays the DHW heater probe temperature (if
present)
Heating mode active
Cooling mode active
Holiday period active
- Delivery set point single zone - without Z1-Z2 on
the side.
- Delivery set point zone 1 if Z1 on the side
- Delivery set point zone 2 if Z2 on the side
Appears when the zone control is enabled and is
always displayed next to the set point (15)
indicator
between
Indicates the selected set point for change
Appears when the zone control is enabled and is
always displayed next to the set point (15)
Cod. 3542B230 - Rev. 00 - 02/2022
Function
-
It can be activated 24h or based on scheduled event.
They only appear of the smart grid function is enabled. The
icons appear based on the status of the dig-in. Hydronic
board EVU and SG.
Shared position on the display. They appear based on the
active function.
Priority index
In the event of simultaneous request
1 anti-freeze
2 defrost
3 silent mode
if crossed out = disabled
They appear depending on the active function.
They cannot be run at the same time.
Displays the DHW setp. during the change.
If DHW=off, OFF appears instead of the temperature.
Shared position on the display.
They appear depending on the active function.
If only the single zone is configured, Z1/Z2 will not be shown
on the side.
If the dual zone is configured, either Z1 or Z2 will always be
shown on the side to indicate which zone the value displayed
refers to.
If single zone, either z1 or z2=off, OFF appears
Indicates that the zone 1 set point is displayed.
Not present if double zone is not enabled.
When a set point appears on the side, it means that it can be
changed. You can move using the SW1-SW2 buttons
Indicates that the zone 2 set point is displayed.
Not present if double zone is not enabled.
Additional NOTE
49