Boiler Service Menu; Menu For Modifying The [Tsp] Parameters - Ferroli OMNIA S HYBRID H 3.2 Installation, Use & Maintenance Manual

Indoor wall unit for split reversible hybrid heat pumps which can be combined with an outdoor dhw heater
Table of Contents

Advertisement

Level 1
Level 2
Burner
Ignition ok
Counters
Ignition error
CH pump time
DHW pump time
Alarm1
XX
Alarm2
YY
Alarm
......
Alarm10
- -
Clear

9.2.2 Boiler service menu

ACCESS TO THE SERVICE MENU AND CHANGING PARAMETERS CAN ONLY BE CARRIED OUT BY QUALIFIED
PERSONNEL.
To continue, you must enter the password "1234". Set the cell value with the SW6 and SW7 buttons while you can change positions with the SW1 and SW2 buttons.
Confirm with the
button.

Menu for modifying the [TSP] parameters

You can scroll the list by pressing the SW1 and SW2 buttons while the value is displayed with the
with the
button or cancel with the
Index Description
b01
Boiler type selection
b02
Boiler type
b03
Gas type
Water system pressure
b04
protection selection (DO NOT MODIFY)
b05
Summer/Winter function
Variable input contact function selection
b06
(NOT USED)
b07
LC32 relay board operation selection
Hours without DHW
b08
withdrawal
b09
Fault 20 status selection
b10
Not implemented
b11
Boiler preparation
b12
Boiler priority
b13
Heating priority
b14
DHW factor (NOT USED)
b15
Not implemented
b16
Not implemented
b17
Not implemented
52
EN
Level 3
Level 4
- -
button.
Modulation
2 = BOILER (DO NOT MODIFY)
1 = 24_H
2 = 28_H
3 = 34_H
4 = 45_H
5 = 24_H (high range)
6 = 28_H (high range)
7 = 34_H (high range)
0 = Methane
1 = LPG
2 = Propane-air
0 = Pressure switch
1 = Pressure transducer
0 = WINTER - SUMMER - OFF
1 = WINTER - OFF
0 = Flowmeter exclusion
1 = System thermostat
2 = Second Room thermostat
3 = Warning/Notification
4 = Thermostat safety device
0 = External gas valve
1 = Alarm
2 = System loading solenoid valve
3 = Solar 3-way valve
4 = Second heating pump
5 = Alarm2
6 = Burner on
7 = Antifreeze active
0-24 hours (time for temporary deactivation of comfort without withdrawal)
0 = Disabled
1 = Enabled (Only for versions with pressure transducer)
--
0 = Fixed primary (P44)
1 = Linked to DHW Set Point (P51)
0 ÷ 255 min
0 ÷ 255 min
0 - 1
--
--
--
Cod. 3542B230 - Rev. 00 - 02/2022
OMNIA S HYBRID H 3.2
Description
Burner operating hours
0
Number of ignitions
Number of failed ignitions
CH pump operating hours
DHW pump operating hours
button. To modify, press the SW6 and SW7 buttons, confirm
Unit
Lower
Upper
Remedy
of meas-
limit
limit
urement
99999
1
hr
Default
2
6
0
1
0 = Enabled
2
0
24
0
--
0
30
15
0
3
--
--
Default
value
-