Ferroli OMNIA S HYBRID H 3.2 Installation, Use & Maintenance Manual page 53

Indoor wall unit for split reversible hybrid heat pumps which can be combined with an outdoor dhw heater
Table of Contents

Advertisement

OMNIA S HYBRID H 3.2
Index Description
DHW mode
b18
activation flow rate
DHW mode
b19
deactivation flow rate
b20
Flue material selection
b21
Not implemented
b22
Not implemented
Maximum temperature
b23
standard flue switch off
Maximum temperature
b24
PVC flue switch off
Maximum temperature
b25
CPVC flue switch off
b26
Not implemented
b27
Calibration procedure [AUTO SETUP]
b28
Not implemented
b29
Restore factory settings
P30
Heating ramp
P31
Heating wait time
P32
Heat post circulation
P33
Pump operation
P34
DeltaT pump modulation
Minimum speed modulating
P35
pump
Start speed modulating
P36
pump
Maximum speed modulating
P37
pump
Pump switch-off temperature
P38
during post circulation
Pump switch-on hysteresis
P39
temperature during post circulation
User heating maximum
P40
setpoint
P41
Maximum heating power
P42
Anti-Legionella function schedule
P43
Boiler hysteresis
P44
Boiler delivery preparation
P45
DHW wait time
P46
User DHW maximum setpoint
DHW pump
P47
post circulation
P48
DHW maximum power
P49
Not implemented
P50
Not implemented
Solar switch-off
P51
temperature
P52
Not implemented
P53
Not implemented
P54
System pre-circulation time
P55
System filling method
System pressure minimum
P56
limit value
System pressure
P57
rated value
System pressure maximum
P58
limit value
P59
Pump deactivation with OpenTherm
P60
Antifreeze power
Modulation
0-100L/min/10
0-100L/min/10
0 = Standard
1 = PVC
2 = CPVC
--
--
60-110°C
60-110°C
60-110°C
--
5 = Calibration procedure [AUTO SETUP] enabled
All other values = Calibration procedure [AUTO SETUP] disabled
--
Factory reset
0÷80
(e.g. 10=20°C/min, 20=12°C/min, 40=6°C/min, 80=3°C/min)
0-10 minutes
0-255 minutes
0 = Continuous pump (only active in winter mode)
1 = Modulating pump
0 ÷ 40°C
30 ÷ 100%
90 ÷ 100%
90 ÷ 100%
0 ÷ 100°C
0 ÷ 100°C
20 ÷ 90°C
0 ÷ 100%
0 = OFF
1÷7 = Days
0 ÷ 80°C
0 ÷ 100°C
30 ÷ 255 seconds
40 ÷70°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
--
--
--
0 ÷ 60 seconds
0 = Disabled
1 = Automatic
0-8 bar/10 (Only for boilers with water pressure sensor)
5-20 bar/10 (Only for boilers with water pressure sensor)
25-35 bar/10 (Only for boilers with water pressure sensor)
0 ÷ 1
(1 = Circulator deactivated with Open Therm)
0 ÷ 50% (0 = minimum)
Cod. 3542B230 - Rev. 00 - 02/2022
Default
25
20
0
--
--
105
93
98
--
0
--
0
40
4
15
1
20
30
90
100
55
25
80
100
0
2
80
120
65
30
100
--
--
10
5
10
30
0
4
7
28
0
0
53