OMNIA S HYBRID H 3.2 INDOOR WALL UNIT FOR SPLIT REVERSIBLE HYBRID HEAT PUMPS WHICH CAN BE COMBINED WITH AN OUTDOOR DHW HEATER INSTALLATION, USE AND MAINTENANCE MANUAL...
Page 2
OMNIA S HYBRID H 3.2 • Read the warnings in this instruction booklet carefully since they pro- • After unpacking, check the good condition of the contents. The pack- vide important information on safe installation, use and maintenance. ing materials are potentially hazardous and must not be left within the •...
OMNIA S HYBRID H 3.2 SUMMARY 1. SAFETY PRECAUTIONS ..................5 7.8 Connection to boiler condensate discharge ..............40 1.1 Special requirements for R32 refrigerant ............... 6 7.9 Electrical connections ....................40 1.2 Information servicing ....................13 7.9.1 Electrical data ..........40 2.
Page 4
OMNIA S HYBRID H 3.2 10. SETTINGS TO ENTER BEFORE STARTING UP ..........63 10.1 Dip switch setting on indoor unit hydronic board ............63 10.2 Dip switch setting of outdoor unit cooling circuit board ..........64 10.3 Climatic curves ......................65 10.3.1 Temperature curves for heating mode and ECO heating mode .
OMNIA S HYBRID H 3.2 1. SAFETY PRECAUTIONS The precautions listed here are divided into the following types. They are quite important, so be sure to follow them carefully. Meanings of DANGER, WARNING, CAUTION and NOTE symbols. HAZARD Indicates an imminently hazardous situation which if not avoided, will result in death or serious injury.
OMNIA S HYBRID H 3.2 1.1 Special requirements for R32 refrigerant WARNING • Do NOT have refrigerant leakage and open flame. • Be aware that the R32 refrigerant does NOT contain an odour. WARNING The appliance shall be stored so as to prevent mechanical damage and in a well-ventilated room without continu- ously operating ignition sources (example:open flames,an operating gas appliance) and have a room size as speci- fied below.
Page 7
OMNIA S HYBRID H 3.2 Input from installer: - Area of adjacent room B (A ) (m Start roomB Use table 3 to calculate the Input from installer: total minimum floor area (A )requi- mintotal - Total refrigerant charge (m...
Page 8
OMNIA S HYBRID H 3.2 The flow chart uses the following tables: Table 2 - Maximum refrigerant charge allowed in a room based on the surface of the installation area. A [m2] mmax [kg] 0.21 0.41 0.62 0.83 1.04 1.24 1.45...
Page 9
OMNIA S HYBRID H 3.2 HAZARD • Before touching electric terminal parts, turn off power switch. • When service panels are removed, live parts can be easily touched by accident. • Never leave the unit unattended during installation or servicing when the service panel is removed.
Page 10
OMNIA S HYBRID H 3.2 CAUTION Ground the unit. Grounding resistance should be according to local laws and regulations. Do not connect the ground wire to gas or water pipes, lightning conductors or telephone ground wires. Incomplete grounding may cause electrical shocks.
Page 11
OMNIA S HYBRID H 3.2 NOTE About Fluorinated Gasses • This air-conditioning unit contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. Compliance with national gas regulations shall be observed.
Page 12
OMNIA S HYBRID H 3.2 • Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treat- ment is necessary. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
OMNIA S HYBRID H 3.2 • The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. WARNING Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufac- turer.
Page 14
OMNIA S HYBRID H 3.2 9) Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, and adequate temporary solution shall be used.
Page 15
OMNIA S HYBRID H 3.2 The refrigerant charge shall be recovered into the correct recovery cylinders. For appliances containing flammable refrigerants, the system shall be purged with oxygen-free nitrogen to render the appliance safe for flammable refrigerants . This process may need to be repeated several times . Compressed air or oxygen shall not be used for purging refrigerant systems.
OMNIA S HYBRID H 3.2 20) Transportation, marking and storage for units • General. The following information is provided for units that use flammable refrigerants. • Transport of equipment containing flammable refrigerants. Attention is drawn to the fact that additional transportation regulations may exist with respect to equip- ment containing flammable gas.
OMNIA S HYBRID H 3.2 2.2 Components supplied with the indoor unit Q.ty Description Component Indoor unit 6 Indoor unit 10 Use, maintenance and installation manual (this manual) RVL-I PLUS 5 55°C 35°C Energy label 2015 811/2013 Perpendicular tap with filter (system return) Perpendicular tap (system delivery) Brass adaptor 3/8”...
OMNIA S HYBRID H 3.2 2.4 Accessories 2.4.1 Hydraulic kit The hydraulic kit is available on request (code 012050W0 consisting of a gas tap, water inlet tap, pipes and fittings) for the hydraulic connection of the wall-mounted indoor unit. °C °C...
OMNIA S HYBRID H 3.2 3. TECHNICAL DATA AN PERFORMANCE 3.1 Heat pump technical data Models 4.20 6.35 8.40 10.0 Thermal power 0.82 1.28 1.63 2.02 Power absorbed 5.10 4.95 5.15 4.95 Water flow rate 1092 1445 1720 External static pressure Heating capacity 4.30...
OMNIA S HYBRID H 3.2 Indoor unit technical data 06 / 10 Power supply 220/240-1-50 V-ph-Hz Exchanger type Brazed stainless steel plate type Type of pump Electronic circulator (8 mca) System expansion tank volume System water safety valve calibration System hydraulic fittings 1”...
OMNIA S HYBRID H 3.2 0T4D4AWA 0T4D4AWA BLUEHELIX HITECH RRT 28 H BLUEHELIX HITECH RRT 28 H 3.4 Boiler technical data 3.4.1 Table for boiler technical data DESTINATION COUNTRIES PAESI DI DESTINAZIONE IT DE ES BG RO PL GR IT DE ES BG RO PL GR...
OMNIA S HYBRID H 3.2 4. DIMENSIONAL AND PHYSICAL DATA °C °C 231 210 fig. 7 - dimensional data and connections Gas inlet - Ø 3/4” 231 Filling coupling - Ø 1/2” 10 System delivery - Ø 3/4” A6 Condensate drain connection 11 System return - Ø...
OMNIA S HYBRID H 3.2 5. GENERAL VIEW AND INTERNAL UNIT FUNCTIONAL DIAGRAM 5.1 General view TW_out SPHP TW_in VDHP fig. 8 - View without front panel fig. 9 - General view 5.2 Indoor unit functional diagram LEGEND Boiler return...
OMNIA S HYBRID H 3.2 7. INSTALLATION 7.1 Inspections on arrival Upon receipt of the unit it is essential to check that you have received all the material indicated on the accompanying document, and also that it has not been damaged during transport.
OMNIA S HYBRID H 3.2 NOTE For the dismantling of the paneling and for normal maintenance activities the minimum operating spaces must be respected. Select an installation location where the following conditions are met: - Place that allows the maximum lengths allowed for pipes to be respected, con- nections to the temperature probe unit, remote control, etc.
OMNIA S HYBRID H 3.2 7.3 Limits to the length and height difference of refrigerant pipes The length of the refrigerant pipes between the indoor and outdoor units must be as short as possible and is in any case limited by compliance with the maximum height difference values between the units.
OMNIA S HYBRID H 3.2 NOTE Refrigerant pipes containing R32 refrigerant which connect refrigerating system components shall not be considered a source of leaked refrigerant for the purpose of evaluating potential for fire or explosion hazard relative to potential ignition sources within the appliance if the piping within the area of the appliance to be evaluated complies with all of the following;...
OMNIA S HYBRID H 3.2 7.4.1 Airtight test and leakage detection Before setting the system in a vacuum, it is advisable to make sure that the refrigerant circuit is tight, including the connecting joints between the pipes and the indoor unit.
OMNIA S HYBRID H 3.2 7.4.3 Heat insulation In order to avoid the release of cold or heat from the connecting pipeline to the external environment during the operation of the equipment, please take effective insulation measures for the gas pipe and liquid pipe separately: 1) The pipe on the gas side should use closed cell foam insulation material, with B1 glass fire-retardant and heat resistance over 120 °C.
OMNIA S HYBRID H 3.2 The chemical conditioners must ensure complete deoxygenation of the water, they must contain specific protective properties for yellow metals (copper and copper alloys), anti-scaling agents for limescale, neutral PH stabilisers and, in low-temperature systems, specific biocides for use in heating systems.
OMNIA S HYBRID H 3.2 Use clean pipes only. Hold the pipe end downwards when removing burrs Cover the pipe end when inserting it through a wall so that no dust and dirt enter. Use a good thread sealant for sealing the connections. The sealing must be able to withstand the pressures and temperatures of the plant.
OMNIA S HYBRID H 3.2 7.6 Boiler gas connection CAUTION Before making the connection, check that the appliance is pre-configured for operating with the type of gas avail- able. The gas connection must be made to the relevant fitting (see “fig. 7 - dimensional data and connections" on page 24) in compliance with the regulation in force, with a rigid metal pipe or a flexible stainless steel hose pipe, with a gas tap placed between the system and the boiler.
OMNIA S HYBRID H 3.2 Ø 100 Ø 127 Ø 60 Ø 80 041083X0 041006X0 041084X0 fig. 20 - Starter accessories for coaxial pipes Table 5 - Maximum length of coaxial pipes Coaxial 60/100 Coaxial 80/125 Maximum length allowed (horizontal)
Page 37
OMNIA S HYBRID H 3.2 cod. 041082X0 fig. 22 - Starter accessories for separate pipes Before installing, check that the maximum length allowed has not been exceeded with a simple calculation: 1. Completely define the layout of the split flue system, including accessories and outlet terminals.
OMNIA S HYBRID H 3.2 7.7.4 Use of flexible hose pipe Ø50 and Ø60 The calculation shown in the tables below includes the starter accessories with code 041087X0 for Ø50 and code 041050X0 for Ø60. Flexible hose pipe A maximum of 4 metres of flue Ø80 mm can be used between the boiler and the tract to the reduced diameter (Ø50 o Ø60), and a maximum of 4 metres of flue Ø80 mm on the extraction (with the maximum flue length with Ø50 and Ø60) see “fig.
OMNIA S HYBRID H 3.2 7.7.5 Connection to collective chimneys fig. 25 - Example of connection to chimneys ( = Air / = Fumes) Table 9 - Type Type Description Single or collective exhaust flue and wall-mounted extraction Extraction from the installation site using a concentric pipe (which includes the exhaust) and exhaust in a collective chimney with natural draught.
OMNIA S HYBRID H 3.2 7.8 Connection to boiler condensate discharge WARNINGS The boiler has an internal siphon for condensate discharge. Install the flexible hose pipe “B” by connecting it under pressure. Before starting up, fill the siphon with about 0.5 litres of water and connect the hose pipe to the drainage system. The drains connected to the sewer system must be resistant to acid condensate. If the condensate drain is not connected to the waste water drainage system, a neutraliser must be installed.
Page 41
OMNIA S HYBRID H 3.2 All field wiring and components must be installed by a licensed electrician and must comply with relevant local laws and regulations. The field wiring must be carried out in accordance with the wiring diagram supplied with the unit and the instruc- tions given below.
OMNIA S HYBRID H 3.2 7.9.1 Opening the front panel 1. To dismount the front panel of the indoor unit: FUNCTION NOTES TERMINAL Partially unscrew the screws A (see "fig. 27 - removing the front panel"). Pull the panel B out and release it from the upper fixings (see "fig. 27 - removing...
OMNIA S HYBRID H 3.2 • Method C - setting for thermostat temperature control from two zones The request may come, for example, from the two room thermostats of the two system zones to be served. The system will operate in the mode set by the user interface.
OMNIA S HYBRID H 3.2 7.9.4 Heat pump hydronic board P_c P_o P_s P_d 2OFF 1OFF AHS1 AHS2 IBH1 N 3ON 3OFF DFT2 DFT1 CN30 CN11 fig. 34 - Detail of heat pump hydronic board Ref. Port Code Description NOTE...
Page 45
OMNIA S HYBRID H 3.2 Ref. Port Code Description NOTE Reserved CN30 Reserved Reserved Compressor operation (the contact is closed when the compressor is operating) DFT2 Defrost run (the contact is closed when the defrost is enabled) DFT1 Reserved AHS1...
OMNIA S HYBRID H 3.2 7.9.5 Connections to the heat pump board Connect the cable to the appropriate terminals as shown in the following images. SV2 - 3-way diverter valve for heat/cool Fasten the cables securely and pass them through the relevant cable gland.
OMNIA S HYBRID H 3.2 8. USER INTERFACE The user interface consists of 7 keys and a display with dot matrix technology. 8.1 Key function description User interface Key function description ID key Function Function details On MAIN, select/scroll up/down between DHW - SYSTEM or DHW - SYS.
OMNIA S HYBRID H 3.2 Index Icon Description Function Additional NOTE timer Enabled when one of the timer functions is active Eco function Enabled when the ECO function is active It can be activated 24h or based on scheduled event.
OMNIA S HYBRID H 3.2 8.4 DHW and system set point configuration DHW set point (min 30°C, max 60°C) To change the DHW set point, proceed as follows: • press the SW1/SW2 buttons to select the set point • press the SW6/SW7 buttons to change the set point •...
OMNIA S HYBRID H 3.2 9. GENERAL USER MENU To access the user menu, press the button. To scroll the rows using the SW1 and SW2 buttons to access the submenu, press the button. The menu is structured in multiple levels as shown in the following table.
OMNIA S HYBRID H 3.2 Unit Lower Upper Default Level 1 Level 2 Level 3 Level 4 Description Remedy of meas- limit limit value urement Burner Burner operating hours 99999 Ignition ok Number of ignitions Counters Ignition error Number of failed ignitions...
Page 53
OMNIA S HYBRID H 3.2 Index Description Modulation Default DHW mode 0-100L/min/10 activation flow rate DHW mode 0-100L/min/10 deactivation flow rate 0 = Standard Flue material selection 1 = PVC 2 = CPVC Not implemented Not implemented Maximum temperature 60-110°C...
OMNIA S HYBRID H 3.2 Index Description Modulation Default Minimum power 0 ÷ 50% (0 = minimum) DO NOT MODIFY G20/G230: 44 Minimum fan speed (The parameters are automatically updated) G30/G31: 46 DO NOT MODIFY G20/G230: 160 Fan speed acc.
Page 55
OMNIA S HYBRID H 3.2 Unit of Menu Menu Menu Menu Menu Lower Upper Rem- meas- Default Description Level 1 Level 2 Level 3 Level 4 Level 5 limit limit ure- value ment Event 1 Enabled y/n Enable the event...
Page 56
OMNIA S HYBRID H 3.2 Unit of Menu Menu Menu Menu Menu Lower Upper Rem- meas- Default Description Level 1 Level 2 Level 3 Level 4 Level 5 limit limit ure- value ment Enabled y/n yes/no enable the anti-legionella disinfection function...
OMNIA S HYBRID H 3.2 Unit of Menu Menu Menu Menu Menu Lower Upper Rem- meas- Default Description Level 1 Level 2 Level 3 Level 4 Level 5 limit limit ure- value ment Online Units N UNIT IN LINE INFO...
OMNIA S HYBRID H 3.2 Cool mode weekly schedule (Preset Temp. Cool) User menu > Preset temp > Preset Temp Cool The submenu with the 7 days of the week will appear, for each day there are 6 possible events to be set from Event 1 to Event 6 will appear.
OMNIA S HYBRID H 3.2 DHW recirculation pump (Dhw Pump Circ) User menu > Dhw settings > Dhw Pump Circ This function allows you to manage a timed recirculation pump on the domestic hot water ring. There are 12 hourly events that can be set and enabled individually.
OMNIA S HYBRID H 3.2 Operation Parameter User menu > Operation Parameter It allows you to view all the operating parameters of the unit. 9.3.2 Heat pump service menu ACCESS TO THE SERVICE MENU AND CHANGING PARAMETERS CAN ONLY BE CARRIED OUT BY QUALIFIED PERSONNEL.
Page 61
OMNIA S HYBRID H 3.2 Unit of Menu Menu Menu Menu Lower Upper Default Description Remedy measure- Level 1 Level 2 Level 3 Level 4 limit limit value ment 2.1 COOL MODE Enables or disables the cooling mode The set point update time calculated by the 2.2 t_T4_FRESH_C...
Page 62
OMNIA S HYBRID H 3.2 Unit of Menu Menu Menu Menu Lower Upper Default Description Remedy measure- Level 1 Level 2 Level 3 Level 4 limit limit value ment The target water output temperature for heating 8.1 T1S H.A. H °C...
T1SETC2 OMNIA S HYBRID H 3.2 T4C1 T4C2 State:In the setting the wired controller, if T4C2<T4C1,then exchange their value; if T1SETC1<T1SETC2, then exchange their value. Table 11 - Max current input (A) for different level of power input limitation Mod. / Limitation level of input power 9.2 DIP switch settings overview...
OMNIA S HYBRID H 3.2 10.3 Climatic curves The climate related curves can be selected in the user interface. Once the curve is selected, the target water flow temperature in each mode is calculated by the curve. It’s possible to select curves even double zone function is enabled.
OMNIA S HYBRID H 3.2 CLIMATIC CURVES (WTS) HEATING MODE Type of terminal curve id T4 (external air temperature) [°C] selected on remote Set climatic curves climatic control 55.0 54.4 53.7 52.5 51.6 50.6 50.0 53.0 52.4 51.7 50.5 49.6 48.6...
OMNIA S HYBRID H 3.2 10.3.2 Temperature curves for cooling mode CLIMATIC CURVES (WTS) COOLING MODE Type of terminal curve id Set climatic T4 (external air temperature) [°C] selected on remote climatic curves control 16.0 16.0 11.0 11.0 17.0 17.0 12.0...
OMNIA S HYBRID H 3.2 11. COMMISSIONING 11.1 Heat pump commissioning Before starting up for the first time, after a long pause, the following preliminary checks should be carried out on the electrical part and refrigeration part. 11.1.1 Preliminary heat pump checks Refrigerating part •...
OMNIA S HYBRID H 3.2 11.2.3 Successive boiler switch-ons Every time the unit is powered on, the firmware versions (display) are shown. FH (5 sec) will then appear on the display, followed by Fh (300 sec) which indicates the air vent cycle (this cycle is only performed if at least one function, heating and/or DHW are set to ON).
OMNIA S HYBRID H 3.2 • by performing “Restore factory settings” with parameter b29=10 (after performing this step, switch the power supply off and on again for about ten seconds). In each of the above-mentioned cases, b27 automatically switches to 5.
OMNIA S HYBRID H 3.2 Example 1: T1Sh= 50°C dT1Sh= 5°C Texternal air = 5°C In these external air conditions, the heat pump has an operating temperature limit (T1stop) equal to 65°C, so Twoutmax (before switch-off) = minimum value between 65 and 55 = 55°C.
OMNIA S HYBRID H 3.2 12. TROUBLESHOOTING This section provides useful information for diagnosing and correcting certain troubles which may occur in the unit. LCD display off If after touching the keys, the display does not switch on, check that the board is connected to the power supply. Check for the supply voltage using a digital multimeter.
Page 73
OMNIA S HYBRID H 3.2 Symptom 4: the water pressure relief valve opens Possible causes Corrective action The expansion vessel is broken or empty Replace the expansion vessel. Refill the expansion vessel. The filling water temperature in the system is Make sure that the filling water temperature in the system is about 1 or 2 bar.
OMNIA S HYBRID H 3.2 12.3 Heat pump error codes When a safety device is activated, an error code is displayed on the user interface (which does not include an external fault). The table below shows a list of all the errors and corrective actions.
Page 75
OMNIA S HYBRID H 3.2 Unit Malfunction or protection Cause of fault and corrective action Error code in error System accumulation lower temperature probe 1.Check the probe resistance. fault (Tbt2) 2.The probe connector is disconnected. Reconnect it. 3.The probe connector is wet. Remove the water and dry the connector. Apply waterproof adhesive tape.
Page 76
OMNIA S HYBRID H 3.2 Unit Malfunction or protection Cause of fault and corrective action Error code in error Communications error between the hydronic 1.The signal cables of the slave and master units are not correctly connected. After checking that all...
OMNIA S HYBRID H 3.2 12.4 Boiler fault codes The screen displays the fault id code in the event of faults or malfunctions. There are faults which cause permanent blocks (marked with the letter “A”): to reset operation, just press the...
Page 78
OMNIA S HYBRID H 3.2 Fault Fault Possible cause Remedy code “Check the correct position and operation of the delivery sensor and replace Delivery sensor damaged it, if necessary” Overtemperature protec- “No water circulation in the system” “Check the circulator and heating system”...
OMNIA S HYBRID H 3.2 Fault Fault Possible cause Remedy code F65 ÷ Fumes pipe clogged. Low gas pressure. Conden- “Check that the fumes pipes and condensate siphon are not clogged. Check Combustion control spe- sate siphon clogged. Combustion problem or fumes the correct pressure of the gas supply.
OMNIA S HYBRID H 3.2 Residual Risks The machines has been designed with a view to reducing the risks to persons and the environment in which it is installed, to the minimum. To eliminate residual risks, it is therefore advisable to become as familiar as possible with the machine in order to avoid accidents that could cause injuries to persons and/or damage to property.
OMNIA S HYBRID H 3.2 fig. 49 - access to internal components 13.2 Water load and system hydraulic pressure adjustment The loading pressure of the sold system, as shown on the boiler hydrometer, must be about 1.0 bar. If the system pressure drops to values below the minimum, the boiler stops and the display shows fault F37.
OMNIA S HYBRID H 3.2 Fans Carry out a visually inspection of the support grille and unit structure grille. Check the fan bearings and the closure of the box terminal covers and cable glands. Dete- riorated bearings cause noise and abnormal vibrations.
OMNIA S HYBRID H 3.2 13.5 Periodic boiler maintenance To maintain the correct operation of the appliance, a qualified technician must perform an annual check which includes the following checks: • The control and safety devices (gas valve, flow meter, thermostats, etc.) must work correctly.
OMNIA S HYBRID H 3.2 13.6.2 Replacement of the boiler main heat exchanger ☞ INFO Before starting with the following instructions, we recommend organising protective devices to protect the inner parts and the boiler electric box from any accidental water leaks.
OMNIA S HYBRID H 3.2 • Insert the new board and reconnect the electrical connections. fig. 59 - fig. 60 - 13.6.4 Replacement of boiler fan CAUTION Disconnect the electrical power supply and close the gas tap upstream of the valve •...
OMNIA S HYBRID H 3.2 14. WIRING DIAGRAM DISPLAY SCHEDA IDRONICA POMPA DI CALORE °C °C MORSETTIERA UTENTE Boiler key SCHEDA ELETTRONICA CALDAIA Heating circulator Heating temperature sensor Gas valve Ignition/ionization electrode Diverter valve Return sensor Fume temperature sensor Antifreeze kit...
OMNIA S HYBRID H 3.2 15. REFRIGERANT DIAGRAM Indoor unit °C °C Outdoor unit Cooling Heating fig. 65 - LEGEND External temperature probe Compressor External exchanger probe 4-way valve Stop valve (gas) Gas-liquid separator Stop valve (liquid) Heat exchange air side...