Service And Maintenance; Adjustments - Ferroli BLUEHELIX THETA C Manual

Table of Contents

Advertisement

Available languages

Available languages

3. Service and maintenance

All adjustments described in this chapter can only be
B
carried out by qualified personnel.

3.1 Adjustments

Gas conversion
The unit can work with 2
the data plate of the unit. If the unit has to be used with a gas other than the factory-set one, pro-
ceed as follows:
1. Disconnect the power supply and turn off the gas.
2. Remove the front panel (see "Opening the front panel" on page 84 ).
3. Apply the plate for LPG (contained in the document bag) near the technical data plate.
4. Refit the front panel and turn on the power to the boiler.
5. Modify the parameter for the type of gas:
• Put the boiler in standby mode and press the Reset button (detail 6 - fig. 1) for 10 seconds.
• The display shows 100 and "co" flashing; press the "Heating +" button (detail 4 - fig. 1) to
set and display 120.
Then press the "DHW +" button (detail 2 - fig. 1) to set 123.
• Press the Reset button once (detail 6 - fig. 1).
• The display shows tS flashing;
• Press the Reset button once (detail 6 - fig. 1).
• Using the "Heating +" button (detail 4 - fig. 1) scroll to the parameter b03.
• Using the "DHW +" button (detail 4 - fig. 1) set:
0 =G20 - Natural Gas (Default setting)
1 =G30/G31 Liquefied Gas
2 =G230 Propane-air
• Press the "Heating +" button (detail 4 - fig. 1) to confirm (changing the value of parameter
b03,automatically changes the value of parameter b27 to 5).
• Press the Reset button (detail 6 - fig. 1) for 10 seconds.
• Turn the power off for 10 seconds and then back on.
• Wait until the Fh mode has finished.
• Put the boiler in standby mode and activate the complete manual calibration mode by simul-
taneously pressing the "OFF/Summer/Winter" and "Heating +" buttons for 5 seconds.
The display will show the flashing symbols "Au" and "to". After burner ignition (flashing
symbols "Hi+flame+faucet+radiator) the boiler will do the calibration in the three power lev-
els "Hi", "ME" and "Lo". Afterwards, a numerical value will be displayed (at this point the boil-
er is at minimum power "Lo").
• If the CO
values are not within the range table 9, proceed as follows: using the "DHW + and
2
-" buttons. Adjust the CO
pressed, the display will show the modified value and then the icon "Lo" (to indicate the min-
imum power level).
• Increasing the value will decrease the CO
• Press the "Heating +" button to go to Medium/ignition power "ME"; the icon "ME" will ap-
pear on the display and a numerical value will appear when the ignition/intermediate power
is reached.
• Adjust the CO
pressed, the display will show the modified value and then the icon "ME" (to indicate the ig-
nition/intermediate power level).
• Press the "Heating +" button to go to maximum power "Hi", the display will show the icon
"Hi" and a numerical value will appear when the maximum power is reached.
• Using the "DHW + and -" buttons, adjust the CO
"DHW + or -" buttons are pressed, the display will show the modified value and then the
icon "Hi" (to indicate the maximum power level). After adjusting the CO
74
nd
rd
or 3
family gases, which is clearly indicated on the packaging and on
at minimum power (Lo); each time the "DHW + or -" buttons are
2
with the "DHW + and -" buttons. Each time the "DHW + or -" buttons are
2
cod. 3540000272 - Rev. 01 - 01/2024
BLUEHELIX THETA C
level and vice versa.
2
at maximum power (Hi); each time the
2
at maximum power,
2
EN

Advertisement

Chapters

Table of Contents
loading

Table of Contents