Ricoh Lily Service Manual page 440

Aficio color 5106/5206
Table of Contents

Advertisement

OPERATION PANEL SELF-DIAGNOSTIC MODES
3. When you start the operational diagnostic program, the system displays
the point accuracy calibration screen.
a) If the point accuracy calibration is necessary, touch the crosses in the
four corners with the editor pen. This enables the correct touch key
operation in the subsequent self diagnostic program screen.
NOTE: You can press the crosses in any order.
This calibration is independent from the point accuracy of the
standard operation panel screen.
b) When the calibration is unnecessary, press the Clear/Stop key to go to
the menu screen.
Press this part.
Operational Panel Diagnostic Program
Press the crosses in the 4 corners.
SKIP : Clear/Stop Key
Message indicating an instruction to press the crosses in the
four corners.
Pressing the Clear/Stop key skips the menu.
Ver :
.
Please select function and execution key.
Main RAM Read/Write Test
System ROM CHeck Sum Test
Video RAM Read/Write Test
VGA Register Test
LCD Pattern Test
Test
Cont
Operational Panel Diagnostic Menu
Touch Panel Test
LED/Conventional Key Test
CMOS RAM Test
Exec
6-32
10 May 1996
Press this part.
ID CODE :
Exit