10 May 1996
SC370: Bk-TD sensor upper detection abnormal
SC371: Y-TD sensor upper detection abnormal
SC372: M-TD sensor upper detection abnormal
SC373: C-TD sensor upper detection abnormal
- Definition - [B]
TD sensor output (Vt) exceeds 4.5 V during copy cycles.
- Possible causes -
•
TD sensor defective
•
Main control board defective
•
Too much toner in the development unit (accidental)
SC374: Bk-TD sensor lower detection abnormal
SC375: Y-TD sensor lower detection abnormal
SC376: M-TD sensor lower detection abnormal
SC377: C-TD sensor lower detection abnormal
- Definition - [B]
TD sensor output (Vt) becomes lower than 0.5 V during copy cycles.
- Possible causes -
•
TD sensor defective
•
Main control board defective
•
Toner supply system defective
SERVICE CALL CONDITIONS
6-11