Ricoh Lily Service Manual page 421

Aficio color 5106/5206
Table of Contents

Advertisement

10 May 1996
SC382: V
adjustment error
D
- Definition - [D]
When doing the process control self-check, V
of the target after 30 trials. The previous settings for V
used in this case. If there are no previous settings, the defaults are used.
- Possible causes -
High voltage supply board - C/G defective
Main control board defective
SC383: V
adjustment error
L
- Definition - [D]
When performing the process control self-check, V
5 V of the target after 30 trials. The previous settings for V
are used in this case. If there are no previous settings, the defaults are
used.
- Possible causes -
LD drive board defective
IPU board defective
SC384: LD exposure abnormal
- Definition - [D]
When performing the process control self-check, the potentials on the
14-step gradation pattern do not come within the target range.
- Possible causes -
LD drive board defective
IPU board defective
SC390: ID sensor adjustment error
- Definition - [D]
When performing the process control self-check, Vsg adjustment does
not result in 4.0 ± 0.2 V.
- Possible causes -
ID sensor defective
Main control board defective
ID sensor too dirty
SERVICE CALL CONDITIONS
does not come within 5 V
D
L
6-13
, V
, and I
are
G
B
LD
does not come within
, V
, and I
G
B
LD