Daikin R32 Split Series Installer's Reference Manual page 85

Domestic hot water tank
Hide thumbs Also See for R32 Split Series:
Table of Contents

Advertisement

Power consumption control
Sensors
EKHWET90~120BAV3
R32 Split series – Domestic hot water tank
4P680077-1 – 2021.11
When Emergency is set to Manual and a heat pump failure occurs, the
domestic hot water heating stops.
To manually recover it via the user interface, go to the Malfunctioning main
menu screen and confirm whether the booster heater can take over the heat
load or not.
To keep energy consumption low, we recommend to set Emergency to Manual if
the house is unattended for longer periods.
#
Code
[9.5.1]
[4-06]
INFORMATION
The auto emergency setting can be set in the menu structure of the user interface
only.
Power consumption control
See
"6  Application
guidelines"  [
functionality.
#
[9.9.1]
[4-08]
[9.9.2]
[4-09]
Limit when [9.9.1]=Continuous and [9.9.2]=Amp:
#
[9.9.3]
[5-05]
Limit when [9.9.1]=Continuous and [9.9.2]=kW:
#
[9.9.8]
[5-09]
Averaging time
The average timer corrects the influence of ambient temperature variations. The
weather-dependent setpoint calculation is done on the average outdoor
temperature.
0: Manual
1: Automatic
4
  23] for detailed information about this
Code
Power consumption control:
0 No: Disabled.
1 Continuous: Enabled: You can set one
power limitation value (in A or kW) to which
the system power consumption will be
limited for all the time.
Type:
0 Amp: The limitation values are set in A.
1 kW: The limitation values are set in kW.
Code
Limit: Only applicable in case of full time
current limitation mode.
12 A~50 A
Code
Limit: Only applicable in case of full time
power limitation mode.
3 kW~20 kW
10
Configuration
|
Description
Description
Description
Description
Installer reference guide
85