▪ Preparation of the installation, reference data, … About heat mode lock..............21 9.4.1 To turn ON heat mode lock......... 21 ▪ Format: Digital files on https://www.daikin.eu. Use the search About cool mode lock ..............21 function to find your model.
▪ Incomplete flaring may cause refrigerant gas leakage. Daikin website (publicly accessible). ▪ Do NOT re-use flares. Use new flares to prevent ▪ The full set of latest technical data is available on the Daikin refrigerant gas leakage. Business Portal (authentication required).
3 About the box WARNING DANGER: RISK OF BURNING/SCALDING ALWAYS use multicore cable for power supply cables. WARNING WARNING ▪ Before carrying out any maintenance or repair activity, Use an all-pole disconnection type breaker with at least ALWAYS switch off the circuit breaker on the supply 3 ...
4 Unit installation General safety precautions Fluorinated greenhouse gases label Multilingual fluorinated greenhouse gases label Energy label Screw bag. The screws will be used for fixing the electrical wire anchor bands. Drain cap (small) Drain cap (large) Reducer assembly Drain socket Unit installation WARNING Installation shall be done by an installer, the choice of...
5 Piping installation It is recommended to provide at least 150 mm of free space below 4.2.3 To provide drainage the unit (300 mm for heavy snowfall areas). Additionally, make sure the unit is positioned at least 100 mm above the maximum expected NOTICE level of snow.
5 Piping installation If the temperature is higher than 30°C and the humidity is higher 3MXM40, 3MXM52, 3MXM68 than RH 80%, the thickness of the insulation materials should be at Liquid piping 3× Ø6.4 mm (1/4") least 20 mm to prevent condensation on the surface of the Gas piping 1×...
5 Piping installation Reducer no. 2 CAUTION Reducer no. 4 Do NOT connect the embedded branch piping and the Flare nut for Ø12.7 mm Inter-unit piping outdoor unit when only carrying out piping work without connecting the indoor unit in order to add another indoor Coat the threaded connection port of the outdoor unit where the flare unit later.
6 Charging refrigerant NOTICE WARNING: MILDLY FLAMMABLE MATERIAL ALWAYS use a recommended bubble test solution from The refrigerant inside this unit is mildly flammable. your wholesaler. WARNING NEVER use soap water: ▪ The refrigerant inside the unit is mildly flammable, but ▪...
7 Electrical installation 2 Fix the label on the inside of the outdoor unit near the gas and Maximum allowable refrigerant charge amount liquid stop valves. 3MXM40, 3MXM52 2.2 kg 3MXM68, 2MXM68 2.4 kg To check for refrigerant leaks after 4MXM68 2.6 kg charging 4MXM80 3.2 kg...
7 Electrical installation DANGER: RISK OF ELECTROCUTION Component Interconnection Voltage 220~240 V All electrical parts (including thermistors) are powered by cable the power supply. Do NOT touch them with bare hands. Wire size Only use harmonised wire (indoor↔outdoo providing double insulation and DANGER: RISK OF ELECTROCUTION suitable for applicable voltage.
8 Finishing the outdoor unit installation 4 Tighten the terminal screws securely using a Philips Configuration screwdriver. 5 Check that the wires do not disconnect by pulling them lightly. About standby electricity saving 6 Firmly secure the wire retainer to avoid external stress on wire function terminations.
Next commissioning instructions in this chapter, a general 1 Remove the switch cover on the service PCB. commissioning checklist is also available on the Daikin Business Portal (authentication required). 2 Set the heat mode lock switch (SW5-1) to ON. The general commissioning checklist is complementary to...
10 Commissioning NOTICE The piping and wiring work match. ALWAYS operate the unit with thermistors and/or pressure The stop valves (gas and liquid) on the outdoor unit are sensors/switches. If NOT, burning of the compressor might fully open. be the result. Initialization of the Multi system can take several minutes depending on the number of indoor units and options used.
▪ Operate only air conditioner during test run. Do NOT Daikin website (publicly accessible). operate the Hybrid for Multi or the DHW generator ▪ The full set of latest technical data is available on the Daikin during test run. Business Portal (authentication required).
13 Technical data Symbol Meaning Symbol Meaning Symbol Meaning Outdoor unit Wire clamp Power module OUTDOOR Switching power supply Residual current PTC* PTC thermistor device Insulated gate bipolar transistor (IGBT) Symbol Colour Symbol Colour Circuit breaker Black Orange Q*DI, KLM Earth leak circuit breaker Blue Pink...