10.4 Preset values and schedules
10.4.1 Using preset values
Installer reference guide
60
Confirm changes and proceed.
About preset values
For some settings in the system, you can define preset values. You only need to set
these values one time, then reuse the values in other screens such as the
scheduling screen. If you later want to change the value, you only have to do it in
one place.
Possible preset values
You can set the following user-defined preset values:
Preset value
Tank target
[5.2] Comfort
temperature,
setpoint
Operation
[5.3] Eco
mode, Quick
setpoint
mode timer
[5.4] Reheat
setpoint
[5.G] Operation
mode
[5.H] Quick mode
timer
Additional to the user-defined preset values, the system also contains some
system-defined preset values that you can use when programming schedules.
Example: In [7.4.2] User settings > Quiet > Schedule (weekly schedule for
when the unit has to use which quiet mode level), you can use the following
system-defined preset values: Quiet/More quiet/Most quiet.
Possible actions on this screen
You can use these preset values in [5.5]
Schedule (weekly schedule screen for
the DHW tank) if the DHW tank mode is
one of the following:
▪
Schedule only
▪
Schedule + reheat
The software uses this preset value if
the DHW tank mode is
Schedule + reheat
You can select two type of DHW
operation which concerns allowance of
booster heater:
▪
Efficient
▪
Quick
This timer is only applicable if "Quick "
is chosen as the Operation mode.
Three preset timer can be selected:
▪
Turbo (10 minutes)
▪
Normal (20 minutes)
▪
Economic (30 minutes)
Where used
EKHWET90~120BAV3
R32 Split series – Domestic hot water tank