Daikin R32 Split Series Installer's Reference Manual page 104

Domestic hot water tank
Hide thumbs Also See for R32 Split Series:
Table of Contents

Advertisement

14
|
Troubleshooting
Installer reference guide
104
Error code
E3-24
High pressure sensor abnormality
E5-00
OU: Overheat of inverter compressor motor
E6-00
OU: Compressor startup defect
E7-00
OU: Malfunction of outdoor unit fan motor
E8-00
OU: Power input overvoltage
EA-00
OU: Cool/heat switchover problem
EC-00
Abnormal increase tank temperature
F3-00
OU: Malfunction of discharge pipe temperature
F6-00
OU: Abnormal high pressure in cooling
F8-00
Compressor internal error
H0-00
OU: Voltage/current sensor problem
H3-00
OU: Malfunction of high pressure switch (HPS)
H6-00
OU: Malfunction of position detection sensor
H8-00
OU: Malfunction of compressor input (CT)
system
H9-00
OU: Malfunction of outdoor air thermistor
HC-00
Tank temperature sensor problem
J3-00
OU: Malfunction of discharge pipe thermistor
J3-10
Compressor port thermistor abnormality
J6-00
OU: Malfunction of heat exchanger thermistor
J6-07
OU: Malfunction of heat exchanger thermistor
J6-32
Leaving water temperature thermistor
Abnormality (outdoor unit)
J8-00
Malfunction of refrigerant liquid thermistor
J9-00
Malfunction of refrigerant gas thermistor 
JA-00
OU: Malfunction of high pressure sensor
L1-00
Malfunction of INV PCB
L3-00
OU: Electrical box temperature rise problem
L4-00
OU: Malfunction of inverter radiating fin
temperature rise
L5-00
OU: Inverter instantaneous overcurrent (DC)
L8-00
Malfunction triggered by a thermal protection
in the inverter PCB
P1-00
Open-phase power supply imbalance
Description
R32 Split series – Domestic hot water tank
EKHWET90~120BAV3
4P680077-1 – 2021.11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ekhwet90bav3Ekhwet120bav3

Table of Contents