Daikin R32 Split Series Installer's Reference Manual page 72

Domestic hot water tank
Hide thumbs Also See for R32 Split Series:
Table of Contents

Advertisement

10
|
Configuration
Installer reference guide
72
#
Code
[5.6]
[6-0D]
See the operation manual for more details.
INFORMATION
When the Priority Schedule is set to DHW (refer to Priority schedule) and the DHW
tank mode is reheat only at same time, the risk for capacity shortage and comfort
problem is significant. In case of frequent reheat operation, space heating/cooling
function is regularly interrupted.
INFORMATION
The application of hysteresis (the amount of the temperature drop that will trigger
the heat up) might vary depending on whether the target temperature is within
operation range of the outdoor unit.
Disinfection
Applies only to installations with a domestic hot water tank.
The disinfection function disinfects the domestic hot water tank by periodically
heating the domestic hot water to a specific temperature.
CAUTION
The disinfection function settings MUST be configured by the installer according to
the applicable legislation.
#
Code
[5.7.1]
[2‑01]
[5.7.2]
[2‑00]
[5.7.3]
[2‑02]
Description
Heat up mode:
0: Reheat
only: Only reheat operation is
allowed.
1: Schedule + reheat: The domestic hot
water tank is heated according to a schedule
and between the scheduled heat up cycles,
reheat operation is allowed.
2: Schedule only: The domestic hot water
tank can ONLY be heated according to a
schedule.
Description
Activation:
0: No
1: Yes
Operation day:
0: Every day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
Start time
EKHWET90~120BAV3
R32 Split series – Domestic hot water tank
4P680077-1 – 2021.11