3 SPECIFICATIONS
3 - 43
Downloaded from
ManualsNet.com
(b) For use of the Q64TCRT(BW)
Platinum
temperature-
Measured
measuring
temperature
resistor type
range
-200.0 to 600.0
Pt100
-200.0 to 200.0
-200.0 to 500.0
JPt100
-200.0 to 200.0
(2) Relative to the stored value or set value of specific buffer memory, the setting
increments is applied as indicated below.
Setting
increments
The value is stored in increments of 1
1
The value indicated without a decimal
0.1
point is stored in increments of 0.1
Example) To specify the temperature for the set value to 200.0 degree Celsius
when the input range is set to 36 (setting increments: 0.1), set Set
value (SV) setting (buffer memory address: 22
For applicable buffer memory, refer to Decimal point position (buffer memory
address: 1
to 4
H
(3) After the input range setting is changed, the temperature process value turns to "0"
for about 8 seconds.
(4) When the input range is changed, the set value of the following setting items might
shift to be outside the setting range, since the setting range shifts along with the
input range change.
If this occurs, the setting item outside the setting range will detect a write data
error (error code: 4).
To avoid this, before changing the input range, set the value of the setting item
within the input range which has been changed.
• Set value (SV) setting (buffer memory address: 22
• Alert set value 1 to 4 (buffer memory address: 26
86
to 89
)
H
H
• AT bias (buffer memory address: 35
• Upper setting limiter (buffer memory address: 37
• Lower setting limiter (buffer memory address: 38
• Loop disconnection detection dead band (buffer memory address: 3C
9C
)
H
(5) To determine the set value change, you must turn on Setting change command
(YnB).
search engine
°C
Input
Setting
range
increments
7
0.1
8
0.1
5
0.1
6
0.1
Stored value
degree Celsius
degree Celsius.
) (Section 3.5.3)
H
, 55
H
MELSEC-Q
°F
Measured
Input
temperature
range
range
-300 to 1100
141
-300.0 to 300.0
143
-300 to 900
140
-300.0 to 300.0
142
Set value
The value is set in increments of 1 degree
Celsuis
The value indicated without a decimal
point is set in increments of 0.1 degree
Celsius.
, 42
, 62
H
H
H
, 42
, 62
, 82
)
H
H
H
H
to 29
, 46
to 49
H
H
H
, 75
, 95
)
H
H
H
, 57
, 77
, 97
)
H
H
H
H
, 58
, 78
, 98
)
H
H
H
H
Setting
increments
1
0.1
1
0.1
, 82
) to 2000.
H
, 66
to 69
,
H
H
H
, 5C
, 7C
,
H
H
H
3 - 43