To perform a ferrite tune, proceed as follows:
Select Menus > Service > Options to display the Service Options menu options which are
1.
listed and described below.
Use the Navigation Keys
2.
the OK / Enter Key
Use the Navigation Keys
3.
/ Enter Key
Navigate to the Menus > Change menu, then use the Navigation Keys
4.
display the Ferrite F product and press the OK / Enter Key
Perform a Full Learn whilst moving the end of the ferrite wand with the sample in and out of
5.
the search head; taking care not to put your hand in or get any watches/rings near the search
head.
On systems fitted with a Product Registration Photo-eye, block the photo-eye to register that
packs are present.
Once a successful Learn has been completed, navigate back to the Menus > Service >
Options menu and de-select the Access Ferrite option.
6.
You have now completed the Ferrite Tune process.

Setting Up Product Signal Tracking

General
This feature allows the detector to automatically adjust the working threshold between two pre-set
limits to enable the sensitivity of the detector to be optimised in situations where the product signal
drifts up and down with the change in product effect.
For instance, for a frozen product the product effect is very small when the product has just come out
of the freezer allowing a low working threshold level to be used giving a high sensitivity to metal
contaminants. However, if the line stops for any reason then the product could thaw slightly, or if the
product were not fully frozen, a significant product signal increase would result. In this event the
working threshold will have to be raised to allow the product to be passed, without false rejection.
Raising the working threshold to allow softer product to pass without false rejection will reduce the
sensitivity to metal contamination, i.e. larger pieces of metal will now be detected. If the product
becomes hard frozen whilst the raised working threshold is still set the sensitivity to metal
contamination will remain reduced because the working threshold is higher than it now needs to be.
Tracking works by recording the product signal for each pack. From the values read the working
threshold continuously trends upwards or downwards between an upper and a lower limit.
The rate and amount by which the working threshold changes, together with limits between which it
operates, are controlled by user entered parameters.
It must be understood that this type of system may allow metal contamination that would otherwise be
detected when the product is fully frozen, to be accepted if product softening has forced the working
threshold to rise.