Logs and Reports
Working Mode Lock
o
Minimum Threshold
o
Maximum Threshold
o
Detection Threshold
o
Product Compensation
o
Phase Angle
o
Phase Lock
o
Head Drive
o
Head Drive Lock
o
Head P Gain
o
Head Q Gain
o
Head RF gain
o
Head Gain Lock
o

Contaminants Report

Purpose

The Contaminants Report contains a complete record of reject activity which is useful for monitoring
and analysing the occurrences and levels of contamination for specific products.

Running the Report

To run the report, navigate to the Menus > Logs > Contaminants menu, scroll down to the
Contaminants Report? menu option and then press the OK / Enter Key. The report will then be
generated and sent over the serial link to the connected device.

Report Contents

The report contains a list of the last inspection records where contaminants were detected, up to a
maximum of 20, under the following column headings:
Date – Displays the date that the report was generated.
Time – Displays the time that the report was generated.
Machine Identification - Displays the Machine ID.
Number of Contaminants - Displays the number of contaminant records included in the
report.
The following details are then provided for each Contaminant included in the report:
Occurred – Displays the date and time that the contaminant was detected.
Threshold – Displays the signal threshold set up for the product.
Peak Signal - Displays the peak signal received when the contaminant was detected.