Adding A New Product - Loma IQ3 User Manual

Table of Contents

Advertisement

Operating Instructions
Product relative
o
If this option is selected, you can set the Reject dwell and delay times to different values
for each product.
Universal
o
If this option is selected, the Reject dwell and delay times set in this menu are initially
used for all products.
Changing the values for one product will then automatically update the values for all
other products and also the values set in this menu.
Reject Confirm
Enable this option if a Reject Confirmation Photo-eye is fitted to your system. This photo-eye
is fitted across the entrance to the reject bin to confirm that the contaminated product has
entered the bin. A system fault is generated if a confirmation signal is not received by the
detector.
Pack check
Select this option to ensure that packs that are counted onto the detector conveyor are
counted off. This option also helps to ensure that packs that should have been rejected, but
did not enter the reject bin, do not leave the detector conveyor by stopping it. This option only
appears if a Product Registration Photo-eye has been fitted and enabled in the Menus >
Service > Configuration > System menu and the Pack Check Photo eye has been installed.
Bin full
Enable this option if a bin full sensor has been fitted to your system. This sensor is fitted
inside the bin towards the top. As contaminated products stack up inside the bin, once they
break the sensor beam a system fault is generated to warn the operator that the bin must be
emptied.
Double bag
Select this option to reject products if the length is longer than expected. For example, bags in
a continuous stream may need to be separated prior to being inspected and this separation
may have failed, resulting in a double-bag entering the detector. This option is only available if
a Product Registration Photo-eye has been installed.
In addition to the above, the following option is available for selection in the Menus > Service >
Reject > Control menu:
Disable rejects?
Selecting this option temporarily disables the reject device. This feature is intended for Loma
Service Engineer use only.

Adding a New Product

This section explains how to add a new product, following which a
capture and save the metal detector settings for inspecting the product.
To add a new product, proceed as follows:
Select Menus > Set Up > Product to display the Product menu options which are listed and
1.
described below.
Use the Navigation Keys
2.
and press the OK / Enter Key
92
Full Learn
to select the Product no (product number) option
to enable the value to be edited.
should be carried out to