Using Performance Validation; Setting Up Pv Testing - Loma IQ3 User Manual

Table of Contents

Advertisement

Operating Instructions

Using Performance Validation

This section describes the benefits of the Performance Validation System and explains how to set up
the metal detector for PV testing, with information about each of the parameters that need to be
specified.
Regular checking of the metal detector's sensitivity should be a normal part of any quality assurance
procedure. This is particularly important should it become necessary to demonstrate due diligence to
address customer or legislative requirements.
One approach is to make regular sensitivity checks and keep handwritten records of the results.
To assist in maintaining quality assurance controls the metal detector includes an automatic
Performance Validation System. This can be set up to automatically prompt the operator to perform
quality assurance checks on a regular basis. It then guides the operator through a test sequence
using standard test samples. At the end of the Performance Validation test the results are saved in
memory and can be outputted in a number of ways.
See the
Logs and Reports

Setting Up PV Testing

To use PV testing the PV Test option must be set to YES in the Menu > Service > Options menu.
The Menus > Set Up > PV Test Set Up menu will then become available.
A series of options the allow you to specify how the performance validation test operates and these
are described below.
The PV Test Set Up menu is not available if the Reverse Mode option has been set to YES
in the Menus > Service > Options menu.
To set up PV testing, proceed as follows:
Select Menus > Set Up > PV Test Set Up to display the PV Test Set Up menu options
1.
which are listed and described below.
Use the Navigation Keys
2.
Enter Key
Use the Navigation Keys
3.
press the OK / Enter
4.
Repeat step 2 and 3 until you have selected and confirmed values for each option.
The PV Test Set Up menu options available are as follows:
Test type
The following options are available for setting the test type to be used.
O Normal
Selecting this option enables the normal test process. The size of the Fe (Ferrite), Nfe
(Non-Ferrite) and S.St (Stainless Steel) test wands being used must first be entered and
menu options are available for these.
When the PV test starts the user will be prompted to pass a sample product pack with
the Fe test wand type attached through the detector where it will be inspected to confirm
that the metal contaminant in the test wand can be detected
102
section for further details.
to enable the value to be edited.
to confirm the selection.
to select each option in turn press the OK /
to select the required option value and then