Parts Identification; Installation - Optex AX-70TN Installation Manual

Hide thumbs Also See for AX-70TN:
Table of Contents

Advertisement

1. PRECAUTIONS
1. Mount unit only on a solid surface.
4. A different type of beam
should not reach the receiver.
receiver
transmitter
transmitter
(other model)

2. PARTS IDENTIFICATION

Pole-mounting Bracket
Mounting Plate
Unit Base
Cover
Optical Unit

3. INSTALLATION

3-1. NOTE
1. Detection range and installation
Distances between the Receiver and the Transmitter
ex) AX-70TN : 70ft.(20m)
2.3ft.-3.3ft. (0.7-1m)
It is not recommendable to install the units in this way
(or direction). In case you do this installation, maximum
detection range shall be half of the original detection range.
(This is to prevent the attenuation of beam by the edge of
the cover.)
3-2. INSTALLATION METHOD
1. Detach the cover and the screw
Optical Unit
Hood
Waterproof Plug
Cover Lock Screw
When removing the cover, do not put your ngers
Note
on the hood, whitch may cause damage.
1) Loosen the cover lock screw to detach the cover.
2) Turn the optical unit and open the waterproof plug.
3) Loosen the unit base lock screw and slide the mounting plate
downward to detach the unit base.
All manuals and user guides at all-guides.com
2. Do not install the unit where objects
moved by the wind such as plants and
laundry, which may block the beam.
5. Avoid aerial wiring.
Wiring
Hole
View Finder
Vertical Alignment
Screw
2. Alignment angle
Horizontally
180 (±90 )
2. Fix the mounting plate
Wall Mounting Screws
Unit Base lock Screw
Wall mounting
3. Prevent direct sunlight
from entering into internal
receiver.
6. Do not install the unit
on unsteady surfaces.
Terminals
•Transmitting
Condition LED
(Transmitter)
•Alarm Indicator LED
(Receiver)
Monitor Jack
(Receiver)
Waterproof Plug
Horizontal
Alignment Dial
・ Pole size should be 1 1/4"-1 7/8" (φ32-48mm).
Vertically
10 (±5 )
Mounting Plate
Lock Screws
Mounting Plate
Pole Lock Screws
Pole mounting (1 plate)
3
7. Mount the units more
than 1m away from the
wall or fence.
3.3 ft. (1m)
Alarm Memory
(Receiver)
(See "7-2 ALARM
MEMORY * TF
ONLY")
Selection Dip Switch
(See "4 WIRE
CONNECTION",
"5-2 BEAM
INTERRUPTION
TIME", and "7-2
ALARM MEMORY *
TF ONLY")
Selection Switch
(See "5-3 4
SELECTABLE BEAM
FREQUENCIES * TF
ONLY")
3. Pole mounting
(Standard U.S. 1 1/4" or 1 1/2"pipe)
about 2.0ft.(60cm)
about 3.3ft.
(1m)
Pole mounting (2 plate)