Download Print this page

Emerson Rosemount 708 Quick Start Manual page 15

Hide thumbs Also See for Rosemount 708:

Advertisement

June 2022
Note
Wireless devices should be powered up in order of proximity from the
Gateway, beginning with the closest device to the Gateway. This will result
in faster network formation.
4.2.1
Mounting in a high temperature application
High temperature mounting hardware should be used when process
temperatures exceed 260 °C (500 °F).
Procedure
1. Place the foot of the transmitter between the standoff mounting
hardware plates as shown in
2. Press standoff plates together so plates and transmitter foot are
aligned.
3. Tighten each screw to 90 in-lb (10.2 N-m).
4. Locate the Rosemount 708 Transmitter and high temperature
mounting hardware on a horizontal section of the piping as close as
possible to the equipment being monitored.
5. Ensure the mounting location is free of foreign matter and corrosion
to ensure good contact between the piping and mounting hardware.
6. Insert the U-bolt through the standoff mounting hardware.
7. Tighten each nut to 90 in-lb (10 N-m)
8. If commissioning the device, install the power module (see
4-5).
9. Ensure the power module cover is fully tightened to prevent
moisture ingress. The lip of the polymer power module cover should
be in contact with the surface of the polymer enclosure to ensure a
proper seal. Do not over tighten.
Quick Start Guide
Figure
4-6.
Figure
4-7.
Quick Start Guide
Figure
15

Advertisement

loading