Charging the battery

Charge batteries only in sufficiently ventilated rooms. Smoking, uncovered lights or fire are not
allowed in these rooms.
Explosive gas is created when charging batteries. Open flames can cause an explosion.
Remove the fill caps when charging batteries that are virtually empty. Leave the fill caps inside
(not empty) batteries that are only charged for maintenance purposes, the fill caps can stay in the
batteries.
The battery can only be charged if the starter switch is in the STOP position and the key re-
moved.
If the battery is charged when installed in the vehicle, the engine compartment cover must be left
open during the charging procedure. After the charging procedure is completed, the engine
compartment cover must be left open for ventilation for about 1 hour prior to start-up. → Risk of
explosion.
Check battery electrolyte level (page 108).
Remove the negative terminal cover and take off the cable clamp. Put the clamp to the side so that contact
with the negative terminal is excluded.
Remove the positive terminal cover.
Connect the battery charger to the battery according to the regulations of the charger manufacturer.
Choose the normal (gentle) charging method.
Clean the battery after charging and replenish the electrolyte, if necessary.

Checking the battery

Charge the battery (page 108).
Check the acid density with a hydrometer. The acid density should be between 1.24 and 1.28 kg/L. If the
acid density differs considerably among the individual cells of a battery, the battery probably has a defect.
Check the affected battery with a battery tester and contact trained personnel.
108
Maintenance
W9212-8235-4
03/2019

Advertisement

Table of Contents
loading

This manual is also suitable for:

U10-3

Table of Contents