Net/Gross; Peak Hold; Units; Hi-Res - Rice Lake MSI-8000HD Technical Manual

Rf remote display
Hide thumbs Also See for MSI-8000HD:
Table of Contents

Advertisement

MSI-8000HD RF Remote Display
4.3.3

Net/Gross

Program an F-key to NetGross
Press Fx-NetGross to toggle between gross and net (gross minus tare). Fx-NetGross only functions if a tare has been
established.
The operator can switch back to gross from net without clearing the tare value. Only clearing or setting a new tare will change
the tare value held before switching into Gross Mode.
4.3.4

Peak Hold

Peak hold uses a high speed mode of the A/D converter allowing it to capture transient loads at a far higher rate than typical
Dynameters.
• Peak Hold is cleared and enabled by pressing Fx-P-HLd
• When a new peak is detected, the Fx LED will flash three times
• The accuracy of the system in peak hold is slightly reduced to 0.2% of Capacity + 5 d
• The filter setting is turned off while in peak hold mode to ensure the fastest acquisition rate
Example: The Peak Hold function is useful in Dynamic and Fall tests. Common tests include Overall Breaking
Strain (OB€), Breaking Force, and Cycled Breaking Strain.
Capture Peak Force:
1. Program an F-key to P-HLd
2. Prepare the stand test and test sample.
3. Press
.
ZERO
4. Press Fx-P-HLd, confirm that Pk is lit on the display.
NOTE: A small jump in the reading occurs depending on the stability of the test device.
5. Apply the test weight. The Fx LED will blink three times when a new peak ID is detected
6. Remove the weight and the peak value is recorded.
7. To run a new test, press Fx-P-HLd to clear the peak value. Repeat
4.3.5

Units

Program an F-key to Unit
(Section 4.3 on page
Press Fx-Unit to set the units parameter to units required for display.
4.3.6

Hi-Res

When set to on, the filter is automatically set to the Hi-1 setting (if Hi-2 is already set, then the filter is not changed). This will
have a small effect on settling time. When set to off, the filter setting resets to the previous filter setting.
Program an F-key to HiRes
Pressing Fx-HiRes places the display into a temporary high resolution mode. This mode continues until Fx-HiRes is pressed
again, or power is cycled. In the Hi-Res mode the appropriate Fx LED blinks continuously at a slow rate.
NOTE:
Hi-Res mode does not increase the accuracy, but allows for smaller weight incrementation to display.
Use
or
to zero out any initial error.
ZERO
TARE
Hi-Res mode is not available when the weighing standard is set to a legal-for-trade standard such as HB-44 or R76
4.3.7

Print

The Print function is set to F-3 key, so there is no need to program F1 or F2 to Print. Then pushing F1 or F2 on the scale will
cause the Comm Port on the Remote to output the selected data string.
If an F-Key is programmed as Print and the Print Setup is configured as continuous, then the F3-Print key is used for Start Print/
Stop Print.