3
Notes
• If the versions shown in (b) and (c) are the same, you do not need to set up. If the version shown in (b) is "-.-.--.---"
or older than the version in (c), you need to set up.
• If the emulator connected to your system is not the E10A-USB emulator suitable for the SH7670, the error
message shown below will be displayed, with the setup tool thereby terminated. In this case, you need to purchase
an "additional device group license tool" separately from the SH7670 CPU board package and use it to set up the
emulator firmware.
• If the error message shown below is displayed, it means that the host computer and the E10A-USB emulator are
not connected together, or the emulator setup switch (SW1) is set to the "0" side. If the emulator setup switch
(SW1) is set to the "0" side, set it to the "1" side and temporarily remove the USB cable and plug it in back again. If
the Add New Hardware Wizard is displayed, refer to the next paragraph (ii), "Setting up the E10A-USB emulator
driver."