NOTE:
When operating in the expanded temperature range, ambient temperature warnings may be reported on the LCD
panel and in the System Event Log.

Expanded operating temperature restrictions

● Do not perform a cold startup below 5°C.
● The operating temperature specified is for a maximum altitude of 3050 m (10,000 ft).
● 145 W and Workstation CPU (160 W) processors are not supported.
● Two power supply units (PSUs) are needed and one PSU failure is not supported.
● Non-Dell qualified peripheral cards and/or peripheral cards greater than 25 W are not supported.
● PCIe SSD and 1.8-inch SSDs are not supported.
● GPU is not supported.