CLOSED COMBUSTION SYSTEM

You should use the closed combustion system for the wood-burning stove if you live in a newly-built, airtight home.
External combustion air is connected through a ventilation pipe via the wall or floor.
We recommend mounting a valve in the ventilation pipe in order to avoid condensate in the stove and the pipe system, when the
stove is not in use. It can also be an advantage to insulate the ventilation pipe.
Minimum Ø 125 mm ventilation pipe, maximum length: 6 metres with a maximum of one bend. We recommend smooth steel
pipes.
Connecting piece for fresh air inlet is loose in the stove.
If the external combustion air is connected at the rear, the dismounted plate must be mounted on the hole for external air in the
bottom of the stove. For wall-mounted model (wall) a special fresh air adapter (accessory) is used.
NOTE: if the stove has a fresh air connexion or closed combustion, the ventilation pipe must be open, when the stove is in use!

EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY

If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim-
ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬
When connecting a pre-fabricated element chimney, follow the manufacturer's connection instructions for the
relevant chimney type.
Scan 87 friskluft
EMNE:

CONNECTION BETWEEN BUILT-IN STOVE AND STEEL CHIMNEY

48038358 mm^2
AREAL:
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that the
chimney will match your wood-burning stove.
10
External
combustion air
via wall
External
combustion air
via floor
NAVN:
MATERIALE:
DIMENSION:
STI:
537,44 kg
04-11-2021
VÆGT:
DATO:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Scan 87
EMNE:
C:\Working Folder\Designs\Scan 87\90087011.idw
90087010
TG.NR:
KEN
SIGN:
If you want external combustion
air via a wall, remove the cover
plate at the rear of the stove with
a pair of cutting pliers
Scan 68
NAVN:
MATERIALE:
Scan 87 produktregistreringsnummer
DIMENSION:
C:\Working Folder\Designs\Scan 68\90068058.idw
STI:
N/A
VÆGT:
N/A
AREAL:
klargøring til vægbeslag
EMNE:
N/A
VÆGT:
N/A
AREAL:
9
TG.NR:
04-11-2021
DATO:
SIG
Krog Iversen & Co A
DK-5492 Vissenbjerg

Advertisement

Table of Contents
loading

Table of Contents