OPEN, AUTO PARTIAL, AUTO, EXIT and OFF modes can be obtained.
Symbol
14
Text
Mode
The door is permanently open. The door can be moved by hand
OPEN
e.g. for window cleaning. All activation units except for the
emergency push button (if fitted) are disconnected.
Two-way traffic, AUTO PARTIAL is obtained. The door can be
AUTOPAR-
opened partially with the inner and outer activation units and
TIAL
with a key switch (if fitted). With an emergency push-button (if
fitted) the door opens fully.
Two-way traffic, normal operation of the door. The door can be
AUTO
opened fully with the inner and outer activation units and with a
key switch/emergency push-button (if fitted).
One-way traffic passage from inside only. The door is normally
EXIT (ONE
locked if an electromechanical locking device has been fitted. The
WAY)
door can only be opened with the inner activation unit or with a
key switch/emergency push-button (if fitted).
The door is closed and locks (if an electromechanical lock is fitted).
This function is only used on emergency escape doors after it is
certain that all people have left the building.
The door cannot be opened with inner and outer activation units.
The door can be opened partially with a key switch (if fitted). The
door can be opened fully with an emergency push button (if fit-
ted).
OMS Basic: When the mode selector is in OFF mode the arrow
OFF
down button can give a key impulse. The key impulse will open
the door to partial open position. There are 3 different ways how
the arrow down button works, depending on configuration.
1
It is not possible to give a key impulse.
2
It is always possible to give a key impulse by pressing the ar-
row down button for 2 seconds.
3
The mode selector must first be unlocked then it is possible
to give a key impulse by pressing the arrow down button for
2 second.
By briefly pushing the dot, placed in the lower right corner of the
operation mode selector, with a narrow object, the operator will
RESET. The operator will start-up again, the doors will return to
closed position with low speed (if operation mode selection is
RESET
not OPEN).
If the operator is equipped with emergency unit for escape, the
operator will test the emergency unit by opening with battery
after the doors have closed with low speed (if operation mode
selection is not OPEN or OFF).
Turn the key clockwise to the position "R" (six o'clock) and insert
a narrow object in the small hole on the operation mode selector
and push briefly. The operator will RESET, then turn the key
counter-clockwise back to the requested setting. The operator
will start-up again, the doors will return to closed position with
low speed (if operation mode selection is not OPEN). If the oper-
RESET
ator is equipped with emergency unit for escape, the operator
will test the emergency unit by opening with battery after the
doors have closed with low speed (if operation mode selection
is not OPEN or OFF).
Note! The key cannot be removed in the "R" position.