Communication ON/OFF
Communication via the COM port can be switched ON (default) or OFF from the PCD.
External communication ON: Type F552 on the PCD.
External communication OFF: Type F553 on the PCD.
Login
To enable login on the MDT, the PCD must be logged out.
Press ESC to display the login prompt.
CDC Login:
Enter Access Code:
Type the access code 1234 (displayed as ****) and confirm with the Enter key.
If the display shows: ! ! ! ! the PCD is logged in.
If the access code was entered successfully the current login level is displayed briefly.
Login level = 1
Whereupon the CDC main menu appears.
Logout
Automatic logout occurs ten minutes after the last key press. The automatic logout can be inhibited
by entering PCD command F561.
To log out manually, select Logout from the main menu by pressing number key 6.
Logout Menu
Current Access Level = 1
Logout ? (Y/N)
Press Y to logout or N to return to the main menu.
Main menu
CDC Main Menu
Door Type
HC11 SW Release
M16C SW Release
Press key to select function:_
1 : Door Operation
2 : Configuration
3 : Diagnostic Functions
4 : Log Functions
5 : Development Functions
6 : Logout
Press the NUMBER KEY 1 to go to the door operation page.
Press ESC to go to this menu from any submenu.
1003090-en-12.0
: RD3/4 - CDC42
: Ver 1.01.39 P1 #7CD3 2017-11-06
: Ver 1.1.7
Issue 2020-10-09