Problems With Windows Server 2003 R2 - NEC Express5800 User Manual

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

8-14 Troubleshooting

Problems with Windows Server 2003 R2

There are some cases that an event log is registered as follows when you operate Windows
Server 2003 R2.
Source:
Type:
Event ID:
Description: The IPMI device driver attempted to determine if the system supported an
→ If you use "Hardware Management" which is provided by Windows Server 2003
R2, above-shown event log will be registered.
For more details, refer to "Enabling Microsoft Windows Server 2003 R2
Hardware Management" on the following site.
[NEC Express5800 Web Site]
http://www.nec.co.jp/express/download/W2K3_R2
IPMIDRV
Error
1001
IPMI BMC device. The driver attempted to detect the presence of the IPMI
BMC by searching the SMBIOS for Type 38 record. But either no record was
found or the record was not compatible with the version of the device driver.
If a SMBIOS Type 38 record was detected, the Dump Data field of the event
contains a binary representation of the record.

Advertisement

Table of Contents
loading

Table of Contents