12.2 Fault, Error & Trouble Shooting
No.
Text
5
DRY – Sync.Reg
System error
6
DRY – Sync.Reg
System error
8
DRY – Sync.Reg
System error
9
DRY – Sync.Reg
System error
DRY - Error in the free
121
rotation at rotor diagnostics
122
DRY - Rotation angle too
small
134
Boot mode activated
135
DRY – Emergency stop:
Mains phase failure
140
DRY: Pump rotates in the
re- verse direction due to
201
DRY - Emergency stop: De-
viation control is too high
202
DRY - Emergency stop:
Drive difference torques is
203
Angular deviation rate limit
too high
204
Angular deviation limit
235
DRY - Emergency stop: Net
phase loss
250
DRY - Emergency stop:
Connection to pump
271
Excess temperature of left
motor
Cause
DRY: Sync.Reg - internal error
ERROR_FLASH_DATATYPES
DRY: Sync.Reg - internal error
ERROR_FLASH_W RITE
DRY: Sync.Reg - internal error
ERROR_FLASH_PARASET:MISMAT
DRY: Sync.Reg - internal error
ERROR_UNEXPECTED_MACHINE
Pump DRY: Rotor diagnostics are
stopped due to the fault, if so
Pump DRY: Rotor diagnostics are
stopped due to the fault, if so
Drives are in the Boot mode
Pump: Mains phase failure
Incorrect direction of rotation of the
motors due to external influences
Pump DRY: The difference in angles
between the pump displacer is too
Pump DRY: The difference in drive
torques in the pump displacer is too
Angular deviation rate limit too high
Angular deviation limit exceeded
permanently
Pump DRY: Net phase loss activates
the con- trolled shut down.
Pump DRY: Pump or device stops as
communication is lost to the Sterling
Temperature monitoring
Flowserve US Inc.
Rectifying measure
Repeat the start-up. Then inform the Service.
Repeat the start-up. Then inform the Service.
Repeat the start-up. Then inform the Service.
Repeat the start-up. Then inform the Service.
Repeat the start-up. If necessary, clean the pump. Then
inform the
Repeat the start-up. If necessary, clean the pump. Then
inform the
Reset boot switch
Check power supply
Check the operating behavior of the system
Clean Pump.
Remove foreign bodies.
Clean the pump. Remove the foreign bodies.
Clean the pump. Remove foreign bodies
Clean the pump. Remove foreign bodies
Control the Bus connection wiring (STERLING link PtP)
between the main STERLING control module and the
Check the operating behavior of the system
76
through
Service
Service
Service
Service
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Operator
Service
Service
Operator