Standard M Series Dry Running Vacuum Pump
Standard
SIHI
Issue Date:
November 21, 2016
3.6.1
Safety Pressure Switch [Purge Type NFPA 496 Completed]
A safety pressure switch, installed within Ex-protection Method Device" Expo – Purge Gas System and is
calibrated to min 2.9 PSIG [200mbarg]
3.6.2
Settings Purge Gas Pressure
The min purge pressure [Leakage Compensation Regulator] is calibrated to 3.6 PSIG
Note:
Calibration of this Leakage Compensation Regulator needs to be checked every six [6] months
for correct pressure [3.6 PSIG] and shall be recalibrated.