6.8 Assembly of pump and seal

When reassembling pump, all fasteners must be
tightened to the proper torque values. Refer to
sectional drawing in section 8.
6.8.1
Bearing handling information
Ball bearings require proper handling and installation
to ensure optimum performance. The following
information is intended as a minimum to ensure that
the bearings are handled and installed properly.
a) Do not remove new bearings from their storage
package except to inspect the bearings, when
stored for a long period of time or just prior to
their installation.
b) Work area must be clean to ensure that no dirt or
other contaminates will enter the bearings.
Handle bearings with clean, dry hands and with
clean, lint free rags. Lay bearing on clean paper
and keep covered. Never expose bearings on a
dirty bench or floor.
c) Do not wash a new bearing. It is already clean
and the preservative should not be removed.
d) Before mounting, be sure shaft bearings areas
are clean and free of nicks and burrs. Check the
dimensions of these areas to ensure correct fit of
bearings.
Under no circumstances are the bearings to
be left exposed; they should be protected by
wrapping or covered.
6.8.2
Bearing installation
a) There is one simple method of providing a heat
source for expanding the inner race of the
bearings to facilitate mounting. Bearings still
wrapped in their original intimate wrap are placed
on a shelf in a temperature-controlled oven. A
temperature of 66 ° C. (150 ° F.) for one-half hour
should be sufficient.
b) When bearings are installed on shaft or journal
sleeve, make sure bearing is installed squarely
and is firmly seated. Hold bearing in place until it
has cooled sufficiently so that it will not move
from position. Cover bearings to protect them
from dirt.
When installing the bearings the mounting
pressure should never be applied in such a manner
that it is transmitted through the balls. Apply the
DMX/DMXD/DMXH/DMXDH USER INSTRUCTIONS ENGLISH 71569282 - 10/09
Page 40 of 60
mounting force directly against, and only against, the
inner ring.
c) When installing bearing housing onto the bearing
and shaft, the bearing housing bores and bearing
outside diameter should be coated with the
grease or lubricating oil to facilitate assembly.
6.8.3
Impeller ring installation
Impellers ring setscrews can be either axial or radial
through the hub.
IMPELLER RING
SET
SCREW
Typical radial screw installation for impeller rings.
IMPELLER RING
SET
SCREW
Typical axial screw installation for impeller rings.
Make sure ring fit on impeller is free of nicks and
burrs. Install the set-screws in the tapered holes on
the ring fits. Radial set screw shall be installed in
such a way that the socket end is accessible from the
inside of the impeller and the point end is just slightly
below the ring fit land. It may be easier to install the
radial set screw from the outside of the impeller.
IMPELLER
IMPELLER RING
SET SCREW
IMPELLER
IMPELLER RING
SET SCREW