(5) 9 - CODE : To make password change. (factory defaults, Install code 1-123456,
Master code 2-135246). If you want to change the password, key-in 6
digits and will automatically show "OK"( max set 6 digits), if the word is
less than 6 digits, you can press ENTER after key-in the number and
it will show "OK".
Press 1 and in the change Install code menu.
Press 2 and in the change Master code menu.
1. SEQUE
: " Sequent " for code learning to set zone location . First of all, all the sensors
needed to be learning into main console, and main console can receive the signal if the
sensor trigger. When sensor is learning into main console, main console will leave the
learning order for the sensor. This system allows to set Zone numbers maximum to 63
addresses. It is recommend that use a pen on the sensor back label to mark the sensor
location, It is available to overlay or clear sensor for changing sensor.
In the learning menu,
Press 1 and into the learning Sequent Mode
The method for sensors learning:
1. PIR Motion Detector (LP-120) :
First to install Battery and push the Power Switch from OFF to C position. PIR
sensor LED will light on for 1 Sec, it means that the sensor transmit 1 sec signal.
Or you can move in the front of PIR, It will detect your movement and transmit 1
sec signal. The sensor will be learned into main console.
2. Door / Window Detector ( LP-123/LP-122/LP-124) :
First to install Battery and let the magnetic switch from close to open, the led will
light on for 1 Sec, The sensor will be learned into main console.
Setting : Change Code
1 – Install
2 – Master
Setting : Change code
1 – Install : 1 2 3 4 5 6
Setting : Change code
2 – Master : 1 3 5 2 4 6
Learning :
1 – SEQUE 2 – OVR 3 - CLR
Learning :
Sequent
Trigger
Sensor
(01 sensor learning order)
11
0 – SET
01