5. To change the BRIX setting, simply readjust the water flow rate. Located on each of the valve assemblies inside the
refrigerated compartment are the adjusting screws for the water flow rate (one per valve).
If the BRIX reading is too high or low, rotate the appropriate water flow control according to Figure 31. Repeat steps 1-5 until the
proper BRIX setting is achieved.
IMPORTANT:
When making changes to the water flow control, do not rotate more than 1/4 turn per adjustment.
Additionally, prior to taking your next BRIX reading, momentarily press the corresponding dispense
button several times prior to drawing a sample. This clears any remnants from the dispense nozzle
AND helps move the flow control to its new setting.
© 2022, Marmon Foodservice Technologies Inc.
QUEST ELITE 4 Flavor Installation, Service & Decommissioning Manual
Water Flow
Controls
Figure 31. BRIX Adjustment
- 31 -
Dispense/Flush Lever
Publication Number:721Q14101MNL