Intended Use Secretion Canister 800 Ml - Atmos C 051 Thorax Operating Instructions Manual

Table of Contents

Advertisement

Warning notes:
The product is:
Sterility / specific microbial
condition:
Single-use product /
reprocessing:
For detailed information on the secretion canister and hose system, please refer to the separate
intended uses.
1.2.2
Intended use secretion canister 800 ml
Name:
Main function:
Intended use / intended
purpose:
Intended users / user profile:
Intended patient group:
Medical condition to be
diagnosed, treated or
monitored:
Application organ:
Application time:
Area of application:
Criteria for patient selection:
6
The following complications may occur during a
cardiothoracic drainage:
• Pain due to irritation of the intercostal nerves
• Injuries to the lung parenchyma / air leakage
• Re-expansion edema
• Effusion retention
• Tension pneumothorax
• Skin / soft tissue emphysema
active
not active
x
q
• Not required for the device.
• Secretion canister and hose system are sterile.
• Options for reprocessing the device according to the
operating instructions.
• Secretion canister and hose system are disposable.
Secretion canister 800 ml
The secretion canister transfers the controlled vacuum
generated by the ATMOS C 051 Thorax. Fluids and air are
drained through the secretion hose and collected in the
secretion canister. The amount of fluid in the secretion
canister can be read and documented on the balancing
scales. An integrated bacterial and viral filter protects the
device from possible contamination and from oversuction.
As a protection, the pop-off valve opens when there is
excess pressure in the secretion canister.
Cover caps are used for proper sealing and disposal.
Collection of fluids and air from the thorax.
Balancing the amount of fluid
• Trained doctors
• Trained healthcare professionals
Users must not be hard of hearing or deaf and must have
adequate vision.
Patients of all ages with and without restrictions.
Accumulated air and fluids in the thorax (pleural cavity,
mediastinum, pericardium) that require controlled
drainage, monitoring, and balancing.
Thorax (pleural cavity. mediastinum, pericardium).
Short-term use on the patient (< 30 days)
The application site is the clinical area. The cardiothoracic
drainage system may only be applied by healthcare
professionals. The secretion canister and the hose system
are sterile and disposable; they can be used in the sterile
OT area.
Patients who require a cardiothoracic drainage (pleura,
mediastinal or pericardial drainage).

Advertisement

Table of Contents
loading

Table of Contents