Installation
1. Install all removed adapters to pilot valve (4).
2. Install pilot valve (4) with washers (11) (2 used) and
socket bolts (10) (2 used).
l : 8 mm
m : 50 N·m (5 kgf·m, 37 lbf·ft)
3. Install pedals (9) (2 used) and levers (8) (2 used) with
bolts, washers (7) (4 used).
j : 17 mm
m : 50 N·m (5 kgf·m, 37 lbf·ft)
SECTION 3 UPPERSTRUCTURE
Group 11 Pilot Valve
WDAA-03-12-017
W3-11-3-3
WDAA-03-12-018