Sensor Extensions
Headsight recommends using the lowest extension setting that allows you to run high as
you desire. Increasing the length of the extension will reduce header control sensitivity.
1. Remove flange lock nut then remove arm and spring.
2. Install extension to sensor assembly with
previously removed spring and flange locknut.
3. Install arm in extension with two bolts and
nuts as pictured at desired length.
•
Headsight does not recommend extensions
unless you need to run higher
•
If you desire to operate header higher then
sensors will allows, you may add extensions
08