Advertisement

Quick Links

CORN
CORN
INSTALLATION MANUAL
GTS
GTS
09020901f
HEADSIGHT.COM | 574.546.5022

Advertisement

Table of Contents
loading

Summary of Contents for Headsight CORN GTS 09020901f

  • Page 1 CORN CORN INSTALLATION MANUAL 09020901f HEADSIGHT.COM | 574.546.5022...
  • Page 3 This icon designates an important instruction. Suggestions If you have any suggestions to improve this manual please call 574-546-5022 or email info@headsight.com. Disclaimers HEADSIGHT, HORIZON, PINPOINT, FORESIGHT, FEATHERSIGHT, TRUESENSE, TERRAHAWK, INSIGHT, the Headsight logo, the Horizon logo, and Terrahawk logo are trademarks of Headsight Harvesting Solutions.
  • Page 4: Table Of Contents

    Table of Contents Installation�������������������������������������������������������������������������������� Mounting Sensors �������������������������������������������������������������������������������02 AllRows �������������������������������������������������������������������������������� Sensor Wiring ����������������������������������������������������������������������������������03 HarnessLengthTable��������������������������������������������������������������������� RemovingWiresforTightAccess����������������������������������������������������������� RoutingWiring�������������������������������������������������������������������������� TerminatingPFGWiring������������������������������������������������������������������ Install Horizon or Insight Controller�������������������������������������������������������������07 Install Light Wiring (Optional) ������������������������������������������������������������������07 Sensor Adjustment ������������������������������������������������������������������������� Changing Swing ���������������������������������������������������������������������������������08 Increasing or Decreasing Voltage ����������������������������������������������������������������08 Sensor Extensions �������������������������������������������������������������������������������09 Mounting Bracket and Harness ������������������������������������������������������������������...
  • Page 5: Installation

    Installation Before working on combine or under header always: 1. Perform all combine and header manufacturer safety precautions for servicing header. 2. Insert stop to prevent movement of header. 3. Turn off combine and remove key from ignition. 4. Set combine parking brake. 5.
  • Page 6: Mounting Sensors

    Mounting Sensors All Rows The Headsight sensor will not fit on the outer two snouts. Install the outer sensors on the second row from each end. 1. Mount sensor on desired rows as shown. • Use supplied M 10 allen head bolt in rear...
  • Page 7: Sensor Wiring

    Sensor Wiring Properly routing the wiring is the most critical part of the installation process. Please take time to ensure that you have allowed sufficient slack for motion as well as sufficient clearance from moving header parts or crop flow. Harness Length Table 1.
  • Page 8: RoutingWiring

    Routing Wiring 1. Lay out wiring to appropriate snout. • Wiring will run from the sensor to the rear of the header near the combine’s feederhouse connection Note: If you are using premade PFBxx cables instead of PFG, you will need to route the wiring in reverse from the following instructions.
  • Page 9 13. Repeat steps above for each sensor. 14. Install the Insight or Horizon Controller if required (see below) and adapter harness (see Headsight combine specific or Horizon manual). 15. Determine wire length and terminate PFG cables as shown below.
  • Page 10: TerminatingPfgWiring

    Terminating PFG Wiring Poor termination will result in field failures. Tight, properly crimped terminals will provide long service with no problems. Using a quality crimp tool will greatly reduce service problems. 1. See Install Controller below for position of main harness. 2.
  • Page 11: Install Horizon Or Insight Controller

    4. Connect Headsight Brown (Stubble) to stubble light lamp wire (if equipped). See the Headsight combine manual for more details about how to install the remaining wiring harness or control box and then connect each individual sensor.
  • Page 12: Sensor Adjustment

    Sensor Adjustment Insert header stop to prevent movement. Changing Swing 1. Loosen the bolt A holding downstop. 2. Slide the downstop to new position in slotted hole. • Raising downstop will increase voltage swing and allow higher maximum cutting height •...
  • Page 13: Sensor Extensions

    Sensor Extensions Headsight recommends using the lowest setting that allows you to run as high as you desire. Increasing the length of the extension will reduce header control sensitivity. 1. Remove flange lock nut then remove arm and spring. 2. Install extension to sensor assembly with previously removed spring and flange locknut.
  • Page 14: Mounting Bracket And Harness

    Parts Mounting Bracket and Harness ITEM QTY. PART NUMBER DESCRIPTION PFBxx (xx=length) Extension Harness (10,17,23,33,38) PFG 38 Unterminated Extension BCGTS Bolt Kit...
  • Page 15: Sensor Parts

    Sensor Parts DATE...
  • Page 16 This Page Is Intentionally Left Blank...
  • Page 17: Statement Of Limited Warranty

    Headsight is for the sole purpose of identifying such goods and shall not create an express warranty that the goods shall conform to such description.
  • Page 18 574.546.5022 • 574.546.5760 4845 3B Rd • Bremen, IN 46506 info@headsight.com www.headsight.com...

Table of Contents