5.3 @ACTV (Counter value inquiry)

(1) Description:
Inquire the counter values of DI0 ~ DI5
(2) Request:
Inquire
@ACTV;Password
Password:login password
Example
Inquire the 6 current counter values of GT-530.
@ACTV;000000
(3) Response:
!MID;ACTV;Result;DI0;DI1;DI2;DI3;DI4;DI5
MID: Machine ID
ACTV:command name
Result:command result
DI0:The DI0 counter value. If the DI is not set as counter, the value is 0.
DI1:The DI1 counter value. If the DI is not set as counter, the value is 0.
DI2:The DI2 counter value. If the DI is not set as counter, the value is 0.
DI3:The DI3 counter value. If the DI is not set as counter, the value is 0.
DI4:The DI4 counter value. If the DI is not set as counter, the value is 0.
DI5:The DI5 counter value. If the DI is not set as counter, the value is 0.
Example :
!GT-530;ACTV;OK;3;3;3;3;3;3
OK
No error
NO
the password is wrong
ER
The format is wrong or authority is not allowed
GT-530 User Manual, Version 1.0, August 2009