4.7 Counter Value

The window provides the function to inquire and modify the counter values of DI0
~ DI5. The explanation of operation and text field is below:
Text field:
(1) Name: The DI name of DI0 ~ DI5。
(2) Value:The current counter value ( maximum: 999999999)
(3) Set Value: Input the defined counter value. The maximum is 999999999. This
field is enabled when DI is set as counter mode.
(4) Counter Alarm: Enable the counter alarm.
(5) Alarm Value: Counter alarm value= current value+ alarm value. This field can
not be 0
Operation:
(1) Read:Read the current counter value and alarm settings from GT-530. If the
counter is not set as counter,the counter value is 0.
(2) Set Value : Change the counter value into GT-530 according to the "Set Value"
field
(3) Set Alarm : Set the counter alarm into GT-530.
GT-530 User Manual, Version 1.0, August 2009
GT-530 user manual v1.0
33/48