Canon imageRUNNER ADVANCE C2000 Series Technical Workbook page 12

Table of Contents

Advertisement

- In case the retransfer residue ghost of different color such as [a] of the sample [C] occurs, proceed with A)
The step for responding to the retransfer residue ghost of different color.
- In case the transfer residue ghost of the same color such as [b] of the sample [C] occurs, proceed with B)
The step for responding to the transfer residue ghost of the same color.
- In case the transfer residue ghost of Black such as [c] of the sample [D] occurs, proceed with C) The step
for responding to the transfer residue ghost of only Black.
A) The step for responding to the retransfer residue ghost of different color
A-1) Change the setting values as described in red in the row "1" of the table below in accordance
with the toner color of which the retransfer residue ghost was confirmed in the step 6), and open and
close the front cover of the main body. This will enable the change of the setting value in Service
Mode. The retransfer residue ghost of Magenta occurred in case of [a] of the sample [C], change the
setting value for Magenta in Service Mode.
B)
Y/M/C/K Upstream
Auxiliary Brush DC
Ghost
bias Adjustment
Settings
Image
Adjust > HV-PRI >
Sample
USUB-Y/KDC
(*1)
1
[C]
2
[C]
3
[C]
[Caution] With regard to "Adjusting Y/M/C Upstream Auxiliary Brush DC bias" described in (*1) of the above
chart, Service Mode USUB-YDC is for adjusting all of Y/M/C at the same time, and USUB-KDC is for
Discharge current
control Y/M/C/K target
current adjustment
Adjust > HV-PRI >
DIS-TGY/M/C/K
-3
-3
-5
Primary Transfer ATVC Y/M/C/K
target current adjustment
(Under Full Color Mode)
Adjust > HV-TR >
1TR-TGY/M/C/K4
0
+3
+5
0
-3
-5
pg. 10